648717
35
Zoom out
Zoom in
Previous page
1/35
Next page
LECOASPIRA PROGRAM
64
ENGLISH
PROBLEM CAUSE SOLUTION
The vacuum does not start No power Check the cable, plug and socket
The suction power drops
The upholstery nozzle, the
flexible tube or the stiff suction
tube are clogged.
The HEPA filter is exhausted
Clen the filter and remove any
obstruction from the tubes and acces-
sories.
Proceed as described in the paragraph
entitled “Cleaning the washable HEPA
filter”.
Water is spilled while sucking up
liquids.
Float device clogged Clean the “EcoActive Filter” water filter
assembly.
The vacuum cleaner shuts down
while vacuuming and the suction
speed indicators (8C) and suc-
tion indicator (8E) flash.
The liquid level in the water
container is too high.
The selected power level is
too high for the surface be-
ing cleaned.
Proceed as described in the section on
“Emptying and cleaning the water con-
tainer” to resume cleaning.
Press the main switch (1), unplug the
power cable and leave the appliance
unplugged for at least 30 seconds to
allow the safety device to reset.
The filling pump of the boiler conti-
nues to operate.
There is air in the boiler circuit.
Switch off the appliance and let it cool,
after which repeat the operations of the
chapter “Switching On”.
The suction stops, even if the dirt
collection container is not full.
Button (A4) of the handle (A2),
is accidentally pressed.
Make sure not to press the button (A4)
during suction.
The machine is pressurized but re-
leases little steam.
The steam adjustment handle
is on Level 1
Turn the steam adjustment handle to
increase the flow of steam
The extension tubes and the ac-
cessories are loose
The locknut is OPEN Turn the locknut to the CLOSED posi-
tion
The extension tubes are hard to at-
tach together or to the flexible hose
The seals produce friction
The locknut is not in the cor-
rect position
Lubricate the seals
Turn the locknut to the correct position
The appliance shuts down and
“E1” appears on the display.
The electronic card has de-
tected low water level in the
boiler.
Turn off the appliance for a few mi-
nutes and then turn it back on. If the
problem appears again, contact an
authorised service centre.
The appliance shuts down and
“E2” appears on the display.
The electronic card has de-
tected an incorrect operating
temperature.
Turn off the appliance for a few mi-
nutes and then turn it back on. If the
problem appears again, contact an
authorised service centre
TROUBLESHOOTING
LECOASPIRA PROGRAM - M0S10133 - 1T10:Layout 1 23/10/2013 9.45 Pagina 64
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Polti Vaporetto Lecoaspira Program at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Polti Vaporetto Lecoaspira Program in the language / languages: English as an attachment in your email.

The manual is 6,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Polti Vaporetto Lecoaspira Program

Polti Vaporetto Lecoaspira Program User Manual - German - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info