a The stove requires a UL listed pellet vent. So the venting system shall be approved for pellet stoves by a certied testing Laboratory.
a PL Vent must be used for venting all Freestanding stoves.
d Do not use to vent pellet appliance these venting materials and products:
- Dryer vent
- Gas appliance (Type B) vent
- PVC (plastic) pipe
- Single wall stove pipe.
a The pellet stove is not the same as other stoves. It has a forced draught of ue gas by a fan, which keeps the rebox in a vacuum
and the entire ueway slightly pressurised. For this reason the ue must be completely airtight and correctly installed to ensure both
trouble-free operation and user safety.
•The ueway must be made by specialised personnel or rms, as outlined below.
•The ue must be installed in such a way as to guarantee that periodic cleaning can be carried out without dismantling any parts whatsoever.
•Pipes should always be sealed with silicone (not cement-based sealants) or specially adapted gaskets/seals, which retain their strength and
elasticity at high temperatures (>450°F / 230°C), and should be xed with at least three sheet metal screws.
a Using the relative pipe clips, x the ue to the wall so that it does not weigh on the smoke fan.
d DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
d DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
d Do not connect to a ueway into which extractor hoods discharge vapours.
a The very hot exhaust gases may cause skin burns: keep a considerable distance away from the appliance.
a The exhaust gases from the combustion of pellets fuel may dirty the outside of the walls. To avoid such possibility terminate the vent
above the roof line.
Pipes and maximum usable lenghts
The exhaust pipe on all stoves is 2.95” O.D. so the stove was designed to accommodate a 3” stove pipe adaptor but the diameters of the pipes
depends on the type of installation. Your installation may require the use of 4” vent as shown in Table 1.
TABLE 1: CONNECTION TO FLUE PIPE - PIPE LENGTH
TYPE OF INSTALLATION WITH 3” DIAMETER PIPE
WITH DOUBLE-WALLED 4”
DIAMETER PIPE
Maximum length (with three 90° elbows) 25’ 35’
For installations more than 4000’ (1200 m) above sea level - Required
Maximum number of elbows 3 4
Length of horizontal sections with minimum 3% gradient 10’ 10’
a Losses in pressure associated with a 90° elbow can be compared to those incurred by three feet of pipe. An inspectable union-tee
can be considered equivalent to a 90° bend.
EXAMPLE: if installing a section greater than 20’ in length with 3” diameter pipe, calculate the maximum usable length in the following ways:
•If a maximum of three 90° elbows are used, the maximum length of the section will be 25’.
•If a maximum of two 90° elbows are used and bearing in mind that a 90° bend can be replaced by 3’ of pipe, the maximum length of the section
will be 25’+3’ = 28’.
•If a maximum of one 90° elbows is used and bearing in mind that a 90° bend can be replaced by one metre of pipe, the maximum length of the
section will be 25’+3’+3’ = 31’.
DT2010229-05
1.7 FLUEwAy
H07029330 / DT2001081 – 02
7
English
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Piazzetta SABRINA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Piazzetta SABRINA in the language / languages: English as an attachment in your email.

The manual is 2,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info