737066
1
Zoom out
Zoom in
Previous page
1/8
Next page
Ph Sf Cpny r eac n s gurte
1. OPENING THE LOCK
1.1. Press«ON» – single acoustic signal and green LED;
1.2. Enter master or user code, consisting of 6...8 symbols (master code
set up in the factory, 1-2-3-4-5-6, the user code is not activated);
1.3. Press«ENTER». After the green LED is activated the lock is ready to
open during 5 seconds.
2. PROGRAMMING
2.1 Master-code programming:
Press «ON»;
Press «ENTER»;
Press «1»;
Press «ENTER»;
Enter valid master-code and press «ENTER»;
Enter new master-code (6 symbols minimum, 8 symbols maximum)
and press«ENTER»;
Enter new master-code again and press «ENTER».
A correct input of the valid or new master-code followed by a double
acoustic signal and green LED. An incorrect input of the actual or new
master-code followed by a single long beep and red L.E.D..
2.2 User-code programming (using master-code)
Press «ON»;
Press «ENTER»;
Press «2»;
Press «ENTER»;
Enter valid master-code and press«ENTER»;
Enter user-code (6 digits minimum and 8 digits maximum) and
press«ENTER»;
Enter user-code again and press «ENTER».
2.3 User-code programming (without using master-code)
Press «ON»;
Press «ENTER»;
Press «3»;
Press «ENTER»;
Enter valid user-code and press«ENTER»;
Enter new user-code (6 minimum, 8 maximum) and press «ENTER»;
Enter new user code again and press «ENTER».
2.4 Deleting the user-code
Press «ON»;
Press «ENTER»;
Press «0»;
Press «ENTER»;
Enter valid master-code and press«ENTER»;
The user code is deleted, only the master-code is valid.
2.5 Dual code programming (master code and user code must al-
ready be programmed to enable this function)
Press «ON»;
Press «ENTER»;
Press «7»;
Press «ENTER» (If only master code is active, there will be a short
acoustic signal and red LED will be turn on. The lock will then turn o,
and the red LED will no longer be visible).
Enter valid master code and press «ENTER»;
2.6 Opening the lock using dual code function:
Press «ON»;
Enter valid master code;
Press «ENTER»;
2.6.1 There will be a short acoustic signal accompanied by green LED.
2.6.2 During the next 60 seconds with intervals of 5 seconds there will be
short acoustic signals accompanied by green LED. During this time a valid
user code must be entered, followed by «ENTER».
2.6.3 If the user code is entered correctly, the lock will open, accompanied
by a short acoustic signal and green LED.
2.6.4 If the user code is not entered or is entered incorrectly during the
60 seconds, there will be a long acoustic signal accompanied by red
LED. The lock then powers down and the opening procedure has to be
repeated from the beginning.
2.6.5 If the master code is entered incorrectly, there will be a long acoustic
signal accompanied by red LED. The lock then powers down.
2.7 Turning o Dual Code:
Press «ON»;
Press «ENTER»;
Press «8»;
Press «ENTER»;
Enter valid master code and press «ENTER»
2.8 Programming of Time delay and Opening time window.
The time delay (TD) function refers to the period of time which must
elapse before the lock can be opened. The opening time window (OTW) is
the period during which the lock may be opened after the TD has elapsed.
Any valid code can be provided with a TD or OTW function.
Press «ENTER»;
Press «6»;
Press «ENTER»;
Enter valid user code or master-code and press «ENTER»;
Enter a 2-digit number that will stand for the TD (01 -99 minutes) and a
number for the OTW (1-9 minutes). For example: 092 – 9 minutes for
TD, and 2 minutes – for the OTW.
Opening with the help of the programmed TD and OTW.
Press «*»;
Input valid user-code or master-code: green visual signal
Automatic start of TD: red visual and acoustic signals every 5 seconds
After end of TD – acoustic signal
Automatic start of OTW: green visual and acoustic signal every 5
seconds
Enter valid code once again during OTW: green visual signal
By pressing «ENTER» during TD period this function is interrupted. The
entire sequence must then be repeated in order to open again.
Cancellation of programmed TD/OTW
Press «ON» ;
Press «ENTER» ;
Press «6» ;
Press «ENTER» ;
Input valid user or master code and press «ENTER»;
Input 0-0-0 for cancelation of TD and OTW.
2.9 Sound O/ On
Push «ON» button ;
Push «ENTER» button ;
Push «5» button ;
Push «ENTER» button ;
Input the actual master-code and push «ENTER» button; Acoustic and
light signals are the same as when programming the master-code.
3. INSUFFICIENT POWER SUPPLY
Low voltage is shown by the red LED and quintuple acoustic signal. There
is still sucient energy for opening. Any change of code is not possible
whilst a low battery indication is displaying.
4. ERROR DIAGNOSES WHEN CHANGING THE ACTUAL
MASTER CODE.
This is the service function and it is indispensable for authenticity of the
master-code input.
Push «ON» button;
Push «ENTER» button;
Push «4» button;
Push «ENTER» button;
Input the service-code «160400» and push «ENTER» button;
If the lock has ever been opened with the help of the actual master-
code, after pushing «ENTER» button-quintuple buzz will follow and the
green L.E.D./ will blink 5 times.
V1 FEB 2019
FS1920E OPERATING INSTRUCTION
& GUARANTEE REGISTRATION
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Phoenix FS1921 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Phoenix FS1921 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 0,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info