316658
5
Zoom out
Zoom in
Previous page
1/32
Next page
5
Storage
- Switch the vacuum cleaner off (fig. 16).
- Remove the mains plug from the wall socket.
- Rewind the mains cord by pressing the
cordwinder pedal (i) (fig. 17).
- Hitch the lower tube onto the vacuum cleaner
(fig. 18-19). You can slide the clip along the
tube to change the height.
Replacing the dustbag
The "dustbag full indicator" will indicate when the
dustbag is full (fig. 20).
- Switch the vacuum cleaner off (fig. 16).
- Remove the hose (fig. 1b).
- Open the cover (fig. 21).
- Remove the cassette with the full dustbag
(fig. 22).
- Remove the full dustbag from the cassette by
pulling the cardboard tag (fig. 23).
This automatically closes the dustbag.
- Discard the full dustbag.
- Slide the cardboard front plate of the new
dustbag into the two slots of the cassette as far
as possible (fig. 24-25).
- Position the cassette and the new dustbag in
the vacuum cleaner (fig. 26).
- Bend the rear part of the dustbag downwards.
- Close the cover ("Click!") (fig. 27).
Note: If no dustbag has been placed into the
cassette, the cover cannot be closed.
Replacing the motor protection filter
After having removed the full dustbag, you can
see the removable holder with the motor
protection filter.
Replace the motor protection filter when placing
the first of a new set of dustbags.
You can take the holder to the dustbin and shake
the filter out there. Hygienic: you need not touch
the filter.
Position the new filter with the white side towards
the dustbag (fig. 28-30).
Press the holder with the new filter firmly into
place to ensure that it fits in correctly at the
bottom.
Replacing the AFS-Micro filter
The indicator will help you determine if the AFS-
Micro filter needs replacing (fig. 31).
One new AFS-Micro filter is supplied with each
set of original Philips dustbags Oslo
+
(type nr.
HR 6938 or servicenr. 4822 015 70049) or Oslo
+
Hygiene (closeable) (type nr. HR 6938-OSH or
service nr. 4822 015 70057).
See figs. 32-33 on how to proceed.
- Position the lower edge of the new filter
properly behind the ridges of the holder.
- When closing the holder, ensure that the filter
fits in completely.
Replacing the mains cord
If the mains cord of this appliance is damaged, it
must only be replaced by Philips or their service
representative, as special tools and/or parts are
required.
For U.K. only:
Fitting a different plug
This appliance is fitted with a BS 1363 13 Amp.
plug.
Should you need to replace the plug, connect the
wires as follows:
Brown wire to the Live (L) terminal of the new
plug.
Blue wire to the Neutral (N) terminal of the new
plug.
Always fit the same value of fuse as that originally
supplied with your appliance.
Only use BS 1362 approved fuses.
As a guide only: Appliances under 700 W can
have a 3 Amp. fuse (red) and all others should
have a 13 Amp. fuse (brown).
When disposing of an old plug (particularly the
moulded type which has been cut from the mains
cord) always remove the fuse as the plug could
be dangerous if ever inserted in a live socket.
Before cutting the plug off, temporarily tie a knot
in the mains cord to prevent it being inadvertantly
drown into the cordwinder.
After fitting the new plug, untie this knot.
Obtaining dustbags / filters
In case you have any difficulties obtaining
dustbags or accessories for this vacuum cleaner,
please either phone 01480 493 000 or write to:
MPP Marketing Ltd., P.O. Box 40, St. Ives,
Huntingdon, Cambridgeshire. PE17 4XS.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Philips hr 8731 vision at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Philips hr 8731 vision in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info