Important
.
Read these instructions for use
carefully before using the appliance
and save them for future reference.
Make sure the appliance does not
get wet (fig. 1).
Remove the batteries from the
appliance if you are not going to
use it for quite some time.
Store and use the appliance at a
temperature between 5cC and
35cC.
Placing the batteries
.
Use 1.5-volt AA (LR6) batteries,
preferably Philips alkaline batteries.
1 Remove the lid of the battery
compartment (fig. 2).
2 Place the batteries (fig. 3).
Make sure the + and - indications on
the batteries match the indications in
the battery holder.
If the batteries have not been placed
correctly, the shaver does not work.
The shaving time provided by a new
set of batteries is approx. 60 minutes.
3 Put the lid of the battery
compartment back onto the
appliance (fig. 4).
Shaving
.
1 Switch the appliance on by
pressing the switch lock and
pushing the on/off slide upwards
(fig. 5).
The switch lock prevents accidental
switching on of the appliance.
2 Move the shaving heads quickly
over the skin, making both
straight and circular movements
(fig. 6).
Shaving on a dry face gives the best
results.
Your skin may need 2 or 3 weeks to
get accustomed to the Philips system.
3 Switch the shaver off.
4 Put the protection cap on the
shaver every time you have used
it, to prevent damage (fig. 7).
Replace the shaving heads (type
HQ4+ Micro Plus) every 2 years for
optimal shaving results. See 'Replacing
the shaving heads'.
Cleaning
.
Regular cleaning guarantees a better
shaving performance.
For easy and optimal cleaning, the
Philips Action Clean (shaving-
head cleaner, type HQ100) is
available. Ask your Philips dealer
for information (fig. 8).
1 Switch the shaver off.
Shaving unit
Clean the shaving unit every week.
1 Clean the top of the appliance
first, using the brush supplied
(fig. 9).
2 Press the release button and
remove the shaving unit (fig. 10).
3 Brush the inside of the shaving
unit clean carefully (fig. 11).
4 Brush the hair chamber clean
carefully (fig. 12).
5 Put the shaving unit back onto
the shaver.
Shaving heads
Clean the shaving heads every two
months.
1 Press the release button and
remove the shaving unit (fig. 10).
2 Press the two sides of the
S-shaped spring together and
remove the retaining frame
(fig. 13).
3 Slide the shaving heads (cutters
and guards) out of the retaining
frame one by one (fig. 14).
Do not mix up the cutters and the
guards.
This is essential since each cutter has
been ground with its corresponding
guard for optimal performance. If you
accidentally mix the sets up, it could
take several weeks before optimal
shaving performance is restored.
4 Clean the cutter with the short-
bristled side of the brush (fig. 15).
5 Brush the guard (fig. 16).
You can also clean the shaving
unit with a degreasing liquid (e.g.
alcohol). If you do, lubricate the
central point of the guards with
adrop of sewing machine oil after
cleaning. This prevents wear of
the shaving heads (fig. 17).
6 Slide the shaving heads back into
the retaining frame and put the
retaining frame back into the
shaving unit (fig. 18).
7 Put the shaving unit back onto
the shaver.
Replacing the shaving heads
.
Replace the shaving heads every two
years for optimal shaving results.
1 Switch the shaver off.
2 Press the release button and
remove the shaving unit (fig. 10).
3 Press the two sides of the
S-shaped spring together and
remove the retaining frame
(fig. 13).
4 Slide the shaving heads out of the
retaining frame (fig. 14).
5 Slide the new shaving heads into
the retaining frame (fig. 18).
6 Put the retaining frame back into
the shaving unit (fig. 19).
7 Put the shaving unit back onto
the shaver.
Replace damaged or worn shaving
heads with Philips HQ4+ Micro Plus
shaving heads only.
Storing
.
Put the protection cap on the
shaver to prevent damage (fig. 7).
Disposal of batteries
.
Only throw the batteries away if they
are completely empty. Do not throw
them away with the normal
household waste but hand them in at
an official collection point.
Troubleshooting
.
1 Reduced shaving performance.
B
Cause 1: the shaving heads are dirty.
Clean the shaver thoroughly
before you continue shaving. See
'Cleaning'.
B
Cause 2: long hairs are obstructing
the shaving heads.
Clean the shaver thoroughly
before you continue shaving (see
'Cleaning').
B
Cause 3: the shaving heads are
damaged or worn and need to be
replaced.
Replace the shaving heads every 2
years for optimal shaving results.
See 'Replacing the shaving heads'.
2 The shaver does not work when
the on/off slide is pushed
upwards.
B
Cause: the batteries are empty.
Replace the batteries. See 'Placing
the batteries'.
3 In case of other problems:
See 'Guarantee & service'.
Accessories
.
The following accessories are available:
- HQ4+ Micro Plus Philips shaving
heads.
- HQ100 Philips Action Clean
(shaving head cleaner).
- HQ101 Philips Action Clean refill
(shaving head cleaning liquid).
- HQ110 Philips shaving head
cleaner (shaving head cleaning
spray).
Guarantee & service
.
If you need information or if you have
a problem, please visit the Philips
Web site at www.philips.com or
contact the Philips Customer Care
Centre in your country (you will find
its phone number in the worldwide
guarantee leaflet). If there is no
Customer Care Centre in your
country, turn to your local Philips
dealer or contact the Service
Department of Philips Domestic
Appliances and Personal Care BV.
Environment
.
Do not throw the appliance away
with the normal household waste
at the end of its life, but hand it in
at an official collection point for
recycling. By doing this you will
help to preserve the environment
(fig. 20).
4222 002 44223
2/5
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Philips HQ40-15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Philips HQ40-15 in the language / languages: Dutch as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info