3
Consistency
Your submersible pump is designated for the circulation of water with a maximum temperature of 35°C. This pump
may not be used for any other fluids and other chemical product.
Installation
The submersible motor pump can be installed as follows:
in a stationary position with fixed pipeline;
in a stationary position with a flexible hose pipe.
NOTE: Never install the pump by suspending it unsupported from its delivery pipe or power cable. The submersible
motor pump must be suspended from the specially provided handle or be placed on the bottom of the shaft.
To guarantee that the pump works properly, the bottom of the shaft must be kept free of sludge and dirt. If the
water level sinks too far, any sludge in the shaft will dry out quickly and stop the pump from starting up. It is
therefore necessary to check the submersible motor pump regularly (by carrying out start-up tests). The
floater is adjusted in a way that the pump can immediately be started. The pump shaft should have minimum
dimensions of 40 x 40 x 50cm so that the floating switch can move freely.
Mains Supply
Your new submersible pump is equipped with a shock-proof plug according to regulations. The pump is designed to
be connected to a 230VAC~50Hz safety socket. Make sure that the socket is sufficiently secured (min. 6A) and is in
excellent condition. Insert the plug into the socket to operate the pump.
NOTE: If the mains cable or plug suffers any damage from external action, repairs to the cable are prohibited. This
work may only be performed by a qualified electrician.
Areas of Use
This pump is used primarily as cellar pump. When installed in a shaft, this pump provides protection from flooding.
The pump can also be used wherever water has to be moved from one place to another, e.g. in the home,
agriculture, horticulture, plumbing and many other applications.
Setting to Work
After having read these instructions carefully, you can set your pump to work, reconsidering the following items:
check if the pump rests on the ground of the shaft;
check if the pressure cord has been attached properly;
check the electrical connection (230VAC~50 Hz);
check if the socket is in good condition;
make sure that water and humidity can never come to the mains supply;
avoid dry-running.
Setting the ON/OFF Operating Point
The ON and OFF operating point of the float switch can be set by adjusting the float switch in its latching holder.
Before putting the pump into operation, please check the following:
The float switch must be installed so that the level of the ON operating point and the level of the OFF operating
point can be reached easily and with little force. To check this, place the pump in a vessel filled with water, raise
the float switch carefully by hand and then lower it again. As you do so, note whether the pump switches on and
off.
Make sure that the distance between the float switch head and the latching holder is not too small. Proper
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Perel GWP3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Perel GWP3 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info