99
installation guide
The appliance can be connected in the following ways:
1 phase connection (1 1N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c.
Install connecting bridges between connection points 1-2 and 4-5.
Your group must be protected by a fuse of at least 32 A. The connecting power
cable must have a minimum core cross section of 6 mm
2
.
2 lives with 2 neutrals connection (2 2N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c. There may be a voltage of 0
V between the phases if they are connected to the same phase in the meter
cupboard but also 400 V if they are connected to 2 different phases. Your
groups must be fused with at least 16 A (2x). The connecting power cable must
have a minimum core cross section of 2,5 mm
2
.
98
installation guide
Electrical connection
For the connection, use an approved cable, in accordance with the regulations.
The cable casing should be of rubber.
There is a label on the underside of the appliance with the wiring diagrams.
The connection terminals are accessible once you have opened the junction
box on the underneath. The junction box cover can be opened with a
screwdriver.
If you want to make a fixed connection, make sure that a multi-polar switch with
a contact separation of at least 3 mm is fitted in the supply line.
Power setting table
Type of hob CKT745 CKT755 CKT770
Cooklight x x x
Eelctrical connection
230 V - 50 Hz x x x
Power of element
Front left 2300 W
Front left double 2200 / 1000 W 2200 / 1000 W
Rear left 1200 W 1200 W 1200 W
Rear right 2000 W 2000 W
Rear right fish pan 2200 / 1400 W
Front right 1200 W 1200 W 2000 W