731739
9
Zoom out
Zoom in
Previous page
1/10
Next page
15 16
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures,
objects and people.
a The ISM (industrial, scientific and medical) bands between 0,15 MHz
and 80 MHz are 6,765 MHz to 6,795 MHz; 13,553 MHz to 13,567 MHz;
26,957 MHz to 27,283 MHz; and 40,66 MHz to 40,70 MHz. The amateur
radio bands between 0,15 MHz and 80 MHz are 1,8 MHz to 2,0 MHz,
3,5 MHz to 4,0 MHz, 5,3 MHz to 5,4 MHz, 7 MHz to 7,3 MHz, 10,1 MHz
to 10,15 MHz, 14 MHz to 14,2 MHz, 18,07 MHz to 18,17 MHZ, 21,0
MHz to 21,4 MHz, 24,89 MHz to 24,99 MHz, 28,0 MHz to 29,7 MHz and
50,0 MHz to 54,0 MHz.
b The compliance levels in the ISM frequency bands between
150 kHz and 80 MHz and in the frequency range 80 MHz to 2,7
GHz are intended to decrease the likelihood that mobile/portable
communications equipment could cause interference if it is
inadvertently brought into patient areas. For this reason, an
additional factor of 10/3 has been incorporated into the formulae
used in calculating the recommended separation distance for
transmitters in these frequency ranges.
c Field strengths from fixed transmitters, such as base stations for
radio (cellular/cordless) telephones and land mobile radios, amateur
radio, AM and FM radio broadcast and TV broadcast cannot be
predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site
survey should be considered. If the measured field strength in the
location in which the Model PG-IRT1603 Infrared Thermometer is
used exceeds the applicable RF compliance level above, the Model
PG-IRT1603 Infrared Thermometer should be observed to verify
normal operation. If abnormal performance is observed, additional
measures may be necessary, such as re-orienting or relocating the
Model PG-IRT1603 Infrared Thermometer.
d Over the frequency range 150 kHz to 80 MHz, field strengths should
be less than 3 V/m.
Guidance and manufacturer’s declaration – electromagnetic
immunity
The is intended for use
in the electromagnetic environment specified below. The customer
or the user of the Model PG-IRT1603 Infrared Thermometer should
assure that it is used in such an environment.
Model PG-IRT1603 Infrared Thermometer
Immunity
test
IEC 60601
test level
Compliance
level
Electromagnetic environment
- guidance
Conducted
RF IEC
61000-4-6
3 Vrms150
kHz to 80
MHz 6 Vrms
150 kHz to
80 MHz
outside ISM
bandsa
N/A
Portable and mobile RF
communications equipment
should be used no closer to any
part of the Model PG-IRT1603
Infrared Thermometer, including
cables, than the recommended
separation distance calculated
from the equation applicable to
the frequency of the transmitter.
Recommended separation
distance
P
V
d
ú
û
ù
ê
ë
é
=
1
5.3
Radiated
RF IEC
61000-4-3
10 V/m
80 MHZ to
2.7 GHz
10 V/m
P
E
d
ú
û
ù
ê
ë
é
=
1
5.3
80MHz to 800MHz
P
E
d
ú
û
ù
ê
ë
é
=
1
7
800MHz to 2.7GHz
where P is the maximum output
power rating of the transmitter
in watts (W) according to the
transmitter manufacturer and d
is the recommended separation
distance in metres(m).
Field strengths from fixed RF
transmitters, as determined
by an electromagnetic site
a
survey, should be less than
the compliance level in each
b
frequency range
Interference may occur in the
vicinity of equipment marked
with the following symbol:
9


Need help? Post your question in this forum.

Forumrules
1

Forum

pangao-pg-irt1603

Reset search

  • HOW TO CHANGE THE BATTERIES IN THE BOOMCARE PG-IRT 1603 UNIT? Submitted on 5-5-2022 at 14:40

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pangao PG-IRT1603 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pangao PG-IRT1603 in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info