683929
2
Zoom out
Zoom in
Previous page
1/2
Next page
BA 879 410-led HM; DE, GB - 23642 - 2016.05-V01
Hugo Müller GmbH & Co KGSturmbühlstraße 145-149D-78054 VS-SchwenningenTel.: +49 (0) 7720 80 836Fax: +49 (0) 7720 31 083info@hugo-mueller.dewww.hugo-mueller.de
INSTRUCTION MANUAL TRIAC DIMMER [R,L] – 879 410 LED
Operating modes Operating modes
Operation with pushbutton
Pressing the pushbutton shortly turns the load on and off.
Pressing the pushbutton for a long time carries-out a cyclical dimming (as long as the
pushbutton is pressed).
In this operation mode the internal potentiometer defines the lower dimming limit (pushbutton
MEM, NO MEM or MEM PLUS). It avoids flickerings or undesired switching-offs.
Operation with external potentiometer (galvanically isolated)
It is possible to control the load with a 10 k potentiometer.
At the minimum level of the potentiometer the load stays turned off.
By turning the potentiometer, the load increases.
It is necessary to set the built-in potentiometer at minimum.
Operation with internal potentiometer
It is possible to control the load with the internal potentiometer of the dimmer.
By setting the potentiometer to the minimum value, the use of an external potentiometer is
possible.
If you put the potentiometer to any value higher than the minimum value, the potentiometer
will only consider this value. It will ignore the signals of the external potentiometer.
Operation with signal 0 - 10V (galvanically isolated)
0V correspond to a switched off status.
10V correspond to the maximum illumination of the dimmer.
You can use any external, isolated or not isolated voltage source
with 0 - 10 V (SPS, control panel etc.).
In this mode of operation the internal potentiometer defines the minimum dimming level. It avoids
flickerings or undesired switching-offs.
Master-Slave-configuration (galvanically isolated)
This configuration is used, if the maximum load that is supported by one dimmer is exceeded. With
this configuration it is possible to distribute the load across multiple dimmers and extend the load. For
this it is necessary to spread the load into several partial loads with each dimmer controlling its
maximum load. It is also recommended to use slaves in applications where different loads have to be
controlled. In this mode of operation the internal potentiometer defines the minimum dimming level. It
avoids flickerings or undesired
switching-offs.
Example 1 Example 2 Example 3 Example 4 Example 5
Operation with pushbutton
Place the selector switch in the
desired working mode:
MEM to switch on at the
same level as turned off.
NO MEM to switch on
with maximum power.
MEM PLUS to switch on
at the same level as
turned off and to rebuild
the operating status (turn
on/ off or level of
intensity) after power
failure.
Operation with pushbutton, extended by
slaves
The MASTER dimmer must be set
according to example 1.To configure a
dimmer as SLAVE, the selector switch
must be in SLAVE mode.
It is possible to add an unlimited number
of slaves.
There can be a time delay in the
response if you use a large number of
salves.
The heat development in the installation
box has to be monitored, especially when
using a larger number of dimmers.
It is recommended to realize a spacing
between each dimmer (1 module
spacing).
Operation with potentiometer
The selector switch must be in the
correct position for the
potentiometer
The brightness level depends on the
position of the potentiometer.
Turning the potentiometer clockwise
will increase the light intensity.
A) Operation with ext. potentiometer
B) Operation with int. potentiometer
Operation with 0 - 10V
signal
The selector switch
must be in the
correct position 0 -
10V.
Level 0V
corresponds to the
status switched off.
The light intensity
increases in the
same amount as the
voltage does to 10V.
3-phase-installation controlled by potentiometer
and increased by slaves
Do the installation according to the wiring diagram.
The MASTER dimmer must be configured as in
example 3A. The slaves must be in position SLAVE.
It is recommended to distribute the loads between
the three phases.
In case of three-phase line without electrical neuter,
please contact us.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Paladin 879 410 led at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Paladin 879 410 led in the language / languages: English as an attachment in your email.

The manual is 0,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Paladin 879 410 led

Paladin 879 410 led User Manual - German - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info