TECHNISCHE DATEN
FUNK SCHALTAKTOR /TIMER 1-KANAL
WARNUNG!: Gefährliche Spannung!
Arbeiten am 230 V-Netz nur von Fachpersonal ausführen lassen!
Vor Montage und Demontage Netzspannung freischalten!
Anschlussspannung
Schaltleistung
Reichweite
110-230V~ 50Hz
μ 16A / 250V
Auf freiem Feld: 100m / Innenbereich: ~30m
Ausgänge
Ausschaltverzögerung
Abmessungen
Funkfrequenz
Betriebstemperatur
Funktionen
1 Ausgangskanal
3Sek. ~ 5Min
46 x 46 x 30mm
868,3MHz
-10ºC ~ +45ºC
Schaltaktor, Timer & Signalverstärker KNX-RF
BESCHREIBUNG
• KNX-RF kompatibler Funk Schaltaktor / Timer.
• Steuerbar über jeden KNX-RF (kompatiblen) Sensor: Taster, Fernsteuerung, ...
• Kompatibel mit folgenden Sendern:670 010 rf, 676 010 rf & 673 010 rf.
• Der Schaltaktor kann als KNX-RF Signalverstärker verwendet werden.
SYMBOLERKLÄRUNG / FUNKTION
Betriebsart-Wahlschalter für Verlinkung / Programmierung und Inbetriebnahme (C):
- P: Einlernvorgang / Programmiermodus.
- R: Normalbetrieb mit zusätzlicher Verstärker-Funktion (Repeater-Funktion).
- S: Normalbetrieb.
- E: Verlinkung trennen (Verlinkung zum Empfänger trennen).
- EA: Löschen aller Verlinkungen (Empfänger und Sender).
Funktionswahlschalter (B):
- A: Schalten EIN/AUS.
- B: Timer (3Sek. ~ 5Min.).
Einlerntaste PROG (A) für der Verlinkung / Verbindung mit anderen Funk-Produkten.
INSTALLATION
WARNUNG: Vor Montage- und Installationsarbeiten Spannung freischalten!
Installieren Sie den Funk-Schaltaktor gemäß des dargestellten Schaltplans.
Hinweis: Das Gerät kann auch als reiner Signalverstärker, ohne Anschluss einer
Schaltlast eingesetzt werden.
Schutzart
IP20
673 730 rf
Angewandte Norm
EN 60669-2-1
Kompatibel mit
IEC 14543-3
TECHNICAL DATA
1 - CHANNEL WIRELESS SWITCH / TIMER
Power supply
Relay nominal power capacity
Range
110-230V~ 50Hz
μ 16A / 250V
Free field: 100m / Indoor: ~30m
Channels
Time delay
Dimensions
Radio-Frequency
Working temperature
Functions
1 output channel
3sec ~ 5min
46 x 46 x 30mm
868,3MHz
-10ºC ~ +45ºC
Switch, Timer & RF-KNX Signals Repeater
DESCRIPTION
• Wireless switching or timing actuator compatible with the KNX-RF protocol.
• Control by any RF-KNX sensor: pushbutton, remote control...
• Compatible with sensors: 670 010 rf, 676 010 rf & 673 010 rf.
• RF-KNX signals repeating function is available, which allows increasing the distance
between the sensors and the receivers.
CHARACTERISTICS
Working mode selector switch for the setting-up and commissioning (C):
- P: link programming.
- R: standard operation with repeater function.
- S: standard operation.
- E: one link deletion from the receiver channel.
- EA: all links deletion from the receiver and transmitter channels.
Function type selector knob (B):
- A: Switch ON/OFF.
- B: Timer (3sec ~ 5min).
It has a Programming key (A) for linking other RF devices.
INSTALLATION
Warning: Disconnect the main supply before the installation!
Install the actuator according to the shown wiring diagram.
Note: The connection of the load is optional and will not be required in installations
where only the repeater function is required.
Protection degree IP20
According to the Standard
EN 60669-2-1
Compatible with
IEC 14543-3
L
N
110-230V
LP NC LP
C
A
B
E
EA
S
R
P
Prog
TIME
A
B
673 730 rf
110-230V~ 50Hz
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Paladin 673 730 rf at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Paladin 673 730 rf in the language / languages: English, German as an attachment in your email.

The manual is 2,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info