587135
7
Zoom out
Zoom in
Previous page
1/9
Next page
7
GB
3. Press and hold [SET].
4. Press [s] and [t] for the desired setting.
5. Press [SET].
For temperatures and humidity, the high and low alarms can be set
in sequence. After entering the value for one alarm, you will be
prompted to enter the value for the other.
A weather alarm is activated once set. When the set criteria is met,
an alarm will go off and the current reading will flash together with
the corresponding indicator.
If that happens in the outdoor/channel temperature or humidity
window, the “OUT” indicator will flash to show that the criteria set
for the outdoor thermo-hygrometer has been met. If it is one of the
separate sensors, the [CHANNEL] indicator will flash. Press the
window repeatedly to locate the channel in question.
When a weather alarm goes off, press any button to stop the alarm.
The alarm is still active until you deactivate the function or the
criteria is no longer met.
To do so,
1. Press the window containing the weather element you want to
set.
2. Press [ALARM].
3. Press [ALARM ON/OFF] to deactivate the function.
To turn on the function again, simply follow the same procedure
and press [ALARM ON/OFF].
DISCONNECTED SIGNALS
If without obvious reason the display for the main unit goes blank
or “
” are displayed, press and hold [CHANNEL] to enforce an
immediate search.
If that fails, check:
- All weather instruments are still in place.
- The batteries of the main unit and individual weather instruments
are still good. Replace them if necessary. Press and hold
[CHANNEL] to enforce an immediate search afterwards.
- The transmission is within range and path is cleared of obstacles
and interference. Shorten the distance if necessary.
Then press and hold [CHANNEL] again. The main unit will start
searching for all previously locked weather instruments.
If you want to add an new sensor, press the reset button on the new
sensor and then press channel to enforce the main unit to search.
Note: 1. Do not reset the sensors after the main unit has locked
those sensors, otherwise the main unit will no longer
receive the signal from those sensors.
2. If you have disconnected signals, you cannot clear the
memory.
THE RESET BUTTON
This button is only used when the system is operating in an
unfavorable way or malfunctioning. Use a blunt stylus to hold
down the button. The main unit will return to all default settings
and start searching for signals again.
Before resetting the main unit, you should do the same for all
weather instruments to ensure correct transmission and reception
of signals. Then press reset on the main unit.
SPECIFICATIONS
Temperature
Proposed Operating Range : Indoor ..... -5°C to 50°C
( 23°F to 122°F )
: Outoor ..... -20°C to 60°C
( -4°F to 140°F )
Resolution : 0.1°C (0.2°F)
(indoor and outdoor)
Relative Humidity
Measuring Range : 2 to 98% RH
(indoor and outdoor)
Resolution : 1% RH
(indoor and outdoor)
Dew Point Temperature
Measuring Range : Indoor ..... 0°C to 49°C
( 32°F to 120.2°F )
: Outoor ..... 0°C to 59°C
( 32°F to 138.2°F )
Resolution : 1°C (2°F)
(indoor and outdoor)
Barometric Pressure / Trend
Measuring Range : 795 to 1050 mb
(23.48 to 31.01 inHg)
Resolution : 1 mb (0.03 inHg)
Wind Speed
Measuring Range : 0 to 56 m/s (0 to 125.3 mph)
Resolution : 0.2 m/s (0.4 mph) (typical)
Wind Direction
Measuring Range : 0° to 359° (Degrees)
Digital Resolution : (typical)
Graphical Resolution : 1
Wind Chill Temperature
Measuring Range : -52°C to 60°C (-61.6°F to 140°F)
Resolution : 1°C (2°F)
Rainfall
Daily and Cumulative : 0 to 9999 mm (0 to 393.7 in)
Measuring Range
Rainfall Rate : 0 to 999 mm/hr (0 to 39.37 in/hr)
Measuring Range
Daily and Cumulative : 1 mm (0.04 inch)
Resolution
Rainfall Rate Resolution : 1mm/hr (0.04 m/h) typical
WMR918 :
Weight : 505 g
Dimension : 204 (L) x 139 (W) x 39 (H)
Power : 12V AC / DV adapter
Power backup : 4 x UM3 - “AA” size alkaline battery
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR918 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR918 in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info