10
Zoom out
Zoom in
Previous page
1/11
Next page
10
EN
To view remaining days for records:
Press clock area until DATA LOGGER mode is displayed.
NOTE When DATA LOGGER is full, i.e., no more records can be stored on unit,
DATA LOGGER’ and ‘O Days will flash.
To upload records to PC:
Plug USB and upload onto computer.
NOTE PC program provided must be installed before uploading of records from
main unit.
To clear records:
1. Press clock area until DATA LOGGER is displayed.
2. Press and hold MEM.
3. All LED icons will light up and turn off consecutively (right to left). Delete process
is complete and successful after blinking of last icon .
RESET
Press RESET to return to the default settings.
TROUBLE SHOOTING
PROBLEM SYMPTOM REMEDY
Barometer Strange readings Set unit
Calendar Strange date / month Change language
Clock Cannot adjust clock Disable radio-controlled clock
Cannot auto-synch
1. Adjust batteries
2. Press RESET
3. Manually activate radio
controlled clock
Temp Shows “LL” or “HH” Temperature is out-of-range
Remote
sensor
Cannot locate
remote sensor
1. Check batteries
2. Check if sensors are
within range
PRECAUTIONS
Do not subject the unit to excessive force, shock, dust, temperature or humidity.
Do not cover the ventilation holes with any items such s newspapers, curtains
etc.
Do not immerse the unit in water. If you spill liquid over it, dry it immediately with
a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive materials.
Do not tamper with the unit ’s internal components. This invalidates the
warranty.
Only use fresh batteries. Do not mix new and old batteries.
Images shown in this manual may differ from the actual display.
When disposing of this product, ensure it is collected separately for special
treatment.
Placement of this product on certain types of wood may result in damage to its
finish for which Oregon Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
The contents of this manual may not be reproduced without the permission of the
manufacturer.
Do not dispose old batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
Please note that some units are equipped with a battery safety strip. Remove the
strip from the battery compartment before first use.
NOTE The technical specifications for this product and the contents of the user
manual are subject to change without notice.
SPECIFICATIONS
MAIN UNIT
Dimensions 149 x 198 x 47 mm
(L x W x H) (5.9 x 7.8 x 1.9 inches)
Weight 510 g (1.12 lbs) without battery
INDOOR BAROMETER
Barometer unit mb/hPa, inHg and mmHg
Measuring range 700 – 1050mb/hPa
Accuracy +/- 10 mb/hPa
Resolution 1mb (0.0 inHg)
Altitude setting Sea level
User setting for compensation
Weather display Sunny, Clear night, Partly Cloudy, Cloudy,
Cloudy at night, Rainy and Snowy
Memory Historical data and bar chart for last 24hrs
INDOOR TEMPERATURE
Temp. unit °C / °F
Displayed range 0°C to 50°C (32°F to 122°F)
Operating range -30°C to 60°C (-4°F to 140°F)
Accuracy 0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
Comfort 20°C to 25°C (68°F to 77°F)
Memory Current, Min and Max temp.
Dew Point w/ Min and Max
Alarm Hi / Lo
INDOOR RELATIVE HUMIDITY
Displayed range 2% to 98%
Operating range 25% to 90%
Resolution 1%
Accuracy 25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort 40% to 70%
Memory Current, Min and Max
Alarm Hi / Lo
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization Auto or disabled
Clock display HH:MM:SS
Hour format 12hr AM/PM or 24hr
Calendar DD/MM or MM/DD
Weekday in 5 languages (E, G, F, I, S)
Battery 4 x UM-3 (AA) 1.5V batteries
AC adapter 6V
REMOTE WIND SENSOR UNIT
Dimensions (L x W x H) 178 x 76 x 214 mm (7 x 3 x 8.4 inches)
Weight 100 g (0.22 lbs) without battery
Wind speed unit m/s, kph, mph, knots
Speed accuracy 2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy 16 positions
Transmission of Approx. every 14 seconds
wind speed signal
Memory Max speed gust
Battery 2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
RELATIVE TEMPERATURE
Dimensions 115 x 87 x 118 mm
(L x W x H) (4.5 x 3.4 x 4.6 inches)
Weight 130 g (0.286 lbs) without battery
Temp. unit °C / °F
Displayed range -50°C to 70°C (-58°F to 158°F)
Operating range -30°C to 60°C (-4°F to 140°F)
Accuracy -20°C – 0°C: +/- 2°C (+/- 4.0°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
50°C - 60°C: +/- 3°C (+/- 6.0°F)
Comfort 20°C to 25°C (68°F to 77°F)
Memory Current, Min and Max temp.
Dew Point w/ Max and Min
Wind chill temp. and min
RELATIVE HUMIDITY
Displayed range 2% to 98%
Operating range 25% to 90%
Resolution 1%
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR200A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR200A in the language / languages: English as an attachment in your email.

The manual is 9,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific WMR200A

Oregon Scientific WMR200A User Manual - German - 11 pages

Oregon Scientific WMR200A User Manual - Dutch - 11 pages

Oregon Scientific WMR200A User Manual - French - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info