3
1 2
97 8 10 11 126
3
4
5
13
RESET
KEY
UV SOLAR RAIN TH WIND
Figure 3 – Inside View
1. Power adapter socket (optional)
2. Channel setting slide switches (SW1)
3. Color-coded connector for connecting solar panel
4. Rechargeable battery compartment
5. RESET button
6. KEY button: for wind direction calibration
7. UV sensor socket (not available now)
8. SOLAR sensor socket (not available now)
9. RAIN sensor socket
10. TH (temperature & humidity sensor) socket
11. WIND sensor socket
12. Pairing slide switch (SW4)
13. LED lights (blue/green/red)
TEMPERATURE & HUMIDITY SENSOR
1
2
4
53
Figure 4
1. Screws (Type B)
2. Sensor casing
3. Temperature and humidity sensor
4. Screws (pre-installed)
5. Sensor cable
SOLAR INSTALLATION
For better installation and easier setting up, please
download the user manual for WMR300/WMR300A
from the below link:
http://weather.oregonscientific.com/products_wmr300.asp
To properly install your sensor, you may need some
tools -- including screwdrivers, wrenches and an
electric drill. What you need will depend on how you
mount your sensor.
The transmitter box is capable of transmitting data
wirelessly an approximate operating range of 300m
(984 feet). Ideal placements for the sensor would be in
any location on the roof of a building that is in an open
area away from trees or other obstructions that may
prevent an accurate reading. Also, be sure to locate
the transmitter box in direct sunlight for optimal power
supply from the solar panel.
Solar panel facing: If you reside in the:
North Southern Hemisphere
South Northern Hemisphere
NOTE
Make sure the
thermometer & humidity sensor
is located at least 1.5 meters
above the ground surface to
avoid the ground temperature
affecting accuracy of the
thermometer & humidity sensor.
SET UP TRANSMITTER BOX
The transmitter box can wirelessly transmit data to
the main unit.
Option 1: Install the transmitter box on a pole
1.5MM
Ground
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific THGN301 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific THGN301 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 23.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info