- EXTERNAL SENSOR MODE. (Ambient sensor or radiant floor)
This mode is selected when the internal sensor is not selected and there
is an external sensor connected to the corresponding terminals.
IMPORTANT NOTE: This mode is only available with Heating.
The following symbol is displayed onscreen when EXTERNAL SENSOR
MODE is activated:
The ambient temperature corresponds to the
temperature measured by the external sensor.
In order to enter parameter configuration in EXTERNAL SENSOR
MODE, press the and buttons at the same time for five seconds.
Set ºC, will appear flashing on the screen, the and buttons are
used to choose equipment operation in either º F or º C. Confirm with
OK.
The words Hi Limits will start flashing on the screen. Use the
buttons to select the upper temperature limit that can be programmed.
Confirm with OK.
Then the words Lo Limits will flash on the screen. Again use the
buttons to select the lower temperature limit that can be programmed.
Confirm with OK.
The symbol now flashes on the display. Use the buttons to
select the COMFORT temperature. Confirm with OK.
Then the symbol will flash on the display. The ECO temperature can
be selected with the buttons. Press OK.
The word Diff. will start flashing on the screen. Use the buttons to
select the differential (the difference between the Switch On and Switch
Off temperatures) between the values: 0.6 ºC, 1 ºC, 2 ºC and 3 ºC.
IMPORTANT NOTE: regulation can be limited in this mode for
safety reasons. Thus, the COMFORT temperature cannot be
programmed higher than the Hi Limits temperature and the ECO
temperature cannot be programmed lower than the Lo Limits
temperature. The manual temperature adjustment
is also limited between these two protection temperatures.
This mode has an anti-icing temperature set at 10 ºC, which only takes
effect when the thermostat is switched to Standby .
INTERNAL SENSOR + EXTERNAL SENSOR MODE
(ideal for radiant floor)
This mode is selected by installing the internal sensor jumper and
connecting an external sensor between the corresponding terminals.
IMPORTANT NOTE: This mode is only available with Heating.
The following symbol is displayed onscreen when INTERNAL SENSOR
+ EXTERNAL SENSOR MODE is activated:
The ambient temperature corresponds to the
temperature measured by the internal
sensor.
In order to enter parameter configuration in INTERNAL SENSOR +
EXTERNAL SENSOR MODE, press the and buttons at the same
time for five seconds. Set ºC, will appear flashing on the screen, the
and buttons are used to choose equipment operation in either º F or
º C. Confirm with OK.
The symbol now flashes on the display, together with the Internal
Sensor symbol. Use the buttons to select the COMFORT
temperature. Confirm with OK.
Then the symbol will flash on the display, together with the Internal
Sensor symbol The ECO temperature can be selected with the
buttons. Press OK.
The words Hi Limits will start flashing on the screen, together with the
External Sensor symbol. The buttons are used to select the upper
temperature limit at which the equipment will drop the load when the
external sensor reaches this temperature (this limit may be very useful
for protecting paving, depending on the employed material when radiant
floor is installed). Confirm with OK.
The word Diff. will start flashing on the screen, together with the Internal
Sensor symbol. Use the buttons to select the differential (the
difference between the Switch On and Switch Off temperatures)
between the values 0.2 ºC and 1 ºC in 0.2°C intervals.
IMPORTANT NOTE: this mode will switch off the load for safety
reasons when the external sensor reaches the Hi Limits
temperature. It is recommended that the COMFORT temperature
does not exceed this SWITCH-OFF temperature.
This mode has an anti-icing temperature set at 5 ºC, which only takes
effect when the thermostat is switched to Standby .
MANUAL TEMPERATURE ADJUSTMENT:
Press the or button and Set will be displayed with the
symbol . Press or again until the desired temperature is
selected. This adjustment is made in 0.5ºC steps, after a few seconds,
the screen will, once again, display the ambient temperature.
SELECTING COMFORT AND ECO TEMPERATURES:
To activate the preselected COMFORT or ECO temperature, simply
press the corresponding button. The symbol will appear onscreen for two
seconds, together with the temperature at which it is programmed. In
order to modify the preselected COMFORT or ECO temperatures, follow
the steps described in the OPERATING MODE sections.
RESTORING FACTORY SETTINGS:
To restore the factory values, press for five seconds, until DEL, is
displayed and then reset the unit. The equipment is then configured with
the original factory settings.
TECHNICAL SPECIFICATIONS:
Power supply Two alkaline batteries
LR03(AAA)1.5 V
Breaking power µ 5(1) A 250 Vac
Battery lifetime Approximately one year.
Temperature measurement precision ± 0.5 °C
Temperature update Every 70 seconds.
Resolution 0.1 °C
LCD measurement range: -10 ºC to +50 ºC
Operation type 1B (Micro-switch off)
Output relay energises:
Every time the measurement or temperature adjustment is updated
.
(Three-minute switch-on delay, only in cooling mode)
Regulation type: ON/OFF with adjustable
differential
Regulation temperature Internal sensor: 5°C to 35°C
External sensor: 5ºC to 45 ºC
Upper Tº limit with external sensor 20 ºC to 45 ºC.
Lower Tº limit with external sensor 5 ºC to 20 ºC.
Protection class II according to EN 60335 for
correct installation.
Protection type IP40 according to EN 60529 for
correct installation.
Operating temperature 0 °C to 50 °C.
Contamination situation Normal
External sensor NTC: 10 k 25 ºC.
WARNING: when the load exceeds the maximum breaking
current, contactors are to be used
.
DIMENSIONS:
07/2011 A016.32.55267
ORBIS TECNOLOGIA ELECTRICA, S.A.
Lérida, 61 E-28020 MADRID
Telephone: +34 91 5672277; Fax: +34 91 5714006
E-mail: info@ orbis.es
http://www.orbis.es
27122
85
COTAS DE MONTAJE
13 30 26
17
11
37,5
11
37,5
4
4
2630
4
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Orbis NEO ML plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Orbis NEO ML plus in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info