621194
2
Zoom out
Zoom in
Previous page
1/2
Next page
BATTERY REPLACEMENT
1. Loosen the screw of the battery cover on the back
of the unit. Remove the battery cover by pulling it
off in the direction of the arrow.
Use the supplied screwdriver or use a small
screwdriver to loosen the screw on the battery cover.
2. Remove the battery with a toothpick.
NOTE:
Do not use a pair of metal tweezers or any metal
object such as a small screwdriver.
CAUTION
Dispose of the device, battery, and components
according to applicable local regulations. Unlawful
disposal may cause environmental pollution.
CAUTION
Do not throw the battery into re. The battery may
explode.
3. Insert the battery (CR2032) with the positive (+)
side face up.
4. Replace the battery cover by sliding the catch in
rst, then tighten the screw.
SPECIFICATIONS
Model:
HJ-324U (HJ-324U-ZBULK)
Power Supply: 3VDC (1 lithium battery CR2032)
Measurement
Range:
Steps: 0 to 99,999 steps
Distance: 0.0 to 621.3 miles /
0.0 to 999.9 km
Calories: 0 to 59,999 kcal
Aerobic steps: 0 to 99,999 steps
Pitch: 0.0 to 9,999.9 step/min
(in increments of
0.1 step/min)
Time: 12:00AM to 11:59PM /
0:00 to 23:59
Memory: Previous 21 days (Most recent 7 days on
display)
IT Function: USB connector
Setting Range: Time: 12:00AM to 11:59PM /
0:00 to 23:59
Weight: 22 to 300 lb (in increments
of 1 lb) / 10 to 136 kg (in
increments of 1 kg)
Height: 3'4'' to 6'6'' (in increments
of 1 inch) / 100 to 199 cm
(in increments of 1 cm)
Stride length: 12" to 48" (in increments
of 1'') / 30 to 120 cm (in
increments of 1 cm)
Operating
Tempe ratu re/
Humidity:
14°F to 104°F (-10°C to +40°C) /
30% to 85% RH
Battery Life: Approx. 6 months* (When used for 12 hours a
day, and transferring the results for 30 seconds
once per day)
NOTE:
The supplied battery is for initial use. This battery
can run out within 6 months.
External
Dimensions:
Approx. 3 1/16"(w) × 1 5/16''(h) × 15/32"(d)
(78 mm × 34 mm × 12 mm)
Weight: Approx. 0.9 oz / 27 g (battery included)
Contents: Pedometer, Holder, Strap, Clip, Battery
(CR2032 installed), Screwdriver, and
Instruction manual
Speci cations are subject to change without notice.
* New battery life based on OMRON testing.
FCC STATEMENT
NOTE:
POTENTIAL FOR RADIO/TELEVISION
INTERFERENCE (for U.S.A. only)
This product has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15
of the FCC rules.
These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. The product generates, uses, and can radiate
radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will
not occur in a particular installation. If the product
does cause harmful interference to radio or television
reception, which can be determined by turning the
product on and off, the user is encouraged to try to
correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the product and the
receiver.
Connect the product into an outlet on a circuit
different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV
technician for help.
LIMITED WARRANTY
Your OMRON HJ-324U Pedometer, excluding the
battery, is warranted to be free from defects in materials
and workmanship appearing within 1 year from the
date of purchase, when used in accordance with the
instructions provided with the unit. The above warranties
extend only to the original retail purchaser.
We will, at our option, repair or replace without charge
any Pedometer covered by the above warranties.
Repair or replacement is our only responsibility and your
only remedy under the above warranties.
To obtain warranty service contact Omron’s Customer
Support at 1-800-634-4350. Information for warranty
service is available on our website at
www.omronhealthcare.com.
Enclose the Proof of Purchase. Include a letter, with your
name, address, phone number, and description of the
speci c problem. Pack the product carefully to prevent
damage in transit. Because of possible loss in transit,
we recommend insuring the product with return receipt
requested.
THE FOREGOING IS THE SOLE WARRANTY
PROVIDED BY OMRON IN CONNECTION
WITH THIS PRODUCT, AND OMRON HEREBY
DISCLAIMS ANY OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
IMPLIED WARRANTIES AND OTHER TERMS
THAT MAY BE IMPOSED BY LAW, IF ANY, ARE
LIMITED IN DURATION TO THE PERIOD OF
THE ABOVE EXPRESS WARRANTY.
OMRON SHALL NOT BE LIABLE FOR LOSS OF
USE OR ANY OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT COSTS,
EXPENSES OR DAMAGES.
This warranty provides you with speci c legal rights,
and you may have other rights that vary by jurisdiction.
Because of special local requirements, some of the above
limitations and exclusions may not apply to you.
FOR CUSTOMER SERVICE
Visit our web site at: www.omronhealthcare.com
Call toll free: 1-800-634-4350
OMRON HEALTHCARE, INC.
1925 West Field Court
Lake Forest, IL 60045 U.S.A.
www.omronhealthcare.com
© 2012 OMRON HEALTHCARE, INC.
Made in China
TROUBLESHOOTING TIPS
Problem Probable Cause How to Correct
The low battery
indicator blinks
or appears
continuously.
The battery is low
or worn.
Replace the battery with
a new one (CR2032),
refer to “BATTERY
REPLACEMENT”.
Nothing is
displayed.
Battery saving mode
active.
Press either of
,
or , refer
to “The battery saving
mode” in “READING
THE CURRENT
DISPLAY”.
The polarities of the
battery (+ and -) are
aligned in the wrong
directions.
Insert the battery in
correct alignement,
refer to “BATTERY
REPLACEMENT”.
The battery is worn.
Replace the battery with
a new one (CR2032),
refer to “BATTERY
REPLACEMENT”.
The displayed
values are
incorrect.
The unit is positioned
incorrectly.
Refer to “The unit may
not count steps correctly
in the following
conditions:” in “USING
THE UNIT”.
Irregular movement.
Inconsistent pace. Up
and down movement.
The set values are
wrong.
Check the settings, refer
to “SETTINGS”.
The display is unusual or the buttons do
not operate normally.
Replace the battery with
a new one (CR2032),
refer to “BATTERY
REPLACEMENT”.
Device error.
Reinstall the battery,
refer to “BATTERY
REPLACEMENT”.
Communication error.
Check the display on
your PC and follow the
instruction provided.
Or plug in the USB
Connector once more
and try again.
NOTE:
If the error still occurs
after trying the above,
contact Omron’s
Customer Support.
CARE AND MAINTENANCE
To keep the unit in the best condition and protect the unit from
damage follow the directions listed below:
CAUTION
Do not disassemble or modify the unit.
Changes or modi cations not approved by Omron
Healthcare will void the user warranty.
Clean the unit with a soft dry cloth.
Do not use any abrasive or volatile
cleaners.
Do not immerse the unit or any of
the components in water.
The unit is not waterproof. Do not
wash it or touch it with wet hands. Be careful that water
does not get into the unit.
Store the unit in a safe and dry location.
Avoid the unit being exposed to direct sunlight, high
temperatures, high humidity, water and/or dust.
Do not subject the unit to strong shock, drop, or step
on it.
Replace a worn battery with a new one immediately.
Remove the battery if the unit will not be used for
three months or longer.
Use of the unit must be consistent with the
instructions provided in this manual.
BATTERY LIFE
Low battery indicator
When the low battery indicator appears on the display,
immediately replace the battery with a new CR2032
battery.
Blinking Battery power is low.
Appears
continuously
Battery power exhausted.
The unit stops measurement.
Data cannot be transferred.
NOTES:
Do not remove the battery around 12:00AM. The
measurement results of the day when the battery
was removed will be added to the measurement
results for the day the battery was inserted.
(It is assumed that the battery will be removed and
replaced with a new one on the same day.)
The measurement results are automatically stored
in memory on the hour (e.g. at 12:00AM, 1:00AM,
2:00AM, ... 9:00PM, 10:00PM, 11:00PM).
The measurement results from the hour until the time
the battery is replaced will be deleted for that day.
When the battery is removed, the time will be reset
to “12:00AM”. Reset the time after inserting the
new battery. Refer to “SETTINGS”.
(The measurement results stored in memory and
the weight, height and stride length settings are not
deleted.)
The attached battery is for initial use. The battery
life may be shorter.
POTENTIAL FOR RADIO/TELEVISION
INTERFERENCE (for Canada only)
This digital apparatus does not exceed the Class B limits
for radio noise emissions from digital apparatus as set
out in the interference-causing equipment standard
entitled “Digital Apparatus”, ICES-003 of the Canadian
Department of Communications.
Cet appareil numérique respecte les limites de bruits
radioeléctriques applicables aux appareils numériques
de Clase B prescrites dans la norme sur le materiel
brouilleur:
“Appareils Numériques”, ICES-003 édictée par le
minister des communications.
Changes or modi cations not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
TRANSFERRING DATA TO THE ONLINE SOLUTION
To begin using the software for the rst time, please visit
www.omron tness.com for the initial set-up instructions.
DELETING ALL RESULTS AND SETTINGS
Follow the procedure below to delete all the previous
measurement results and settings, including the date, time,
weight, height, and stride length.
1. Press and hold .
“lb” or “kg” ashes on the display.
2. Press and hold
and at the same time.
After “Clr” has been displayed, “lb” and “kg” ash on
the display.
The measurement results stored in memory and the
settings for the date, time, weight, height and stride
length are deleted. To continue using the unit, reset the
date, time, weight, height, and stride length (refer to
“SETTINGS”).
NOTE:
If a malfunction has occurred and you need to repair
your unit, all settings and measurement results are
deleted. We recommend that you record measurement
results.
Communication
indicator
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Omron HJ-324U at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Omron HJ-324U in the language / languages: English as an attachment in your email.

The manual is 1,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info