8 Technical Data
In the event of a power failure, power continues to be supplied for at least 24 hours by means of an
integrated, rechargeable battery. This ensures a backup of the recordings.
Specifications
Operating voltage: 230 V
AC
/ 50 Hz
Maximum load: 16 A
Rated voltage: 200 V – 250 V
Rated current: 0 A – 16 A
Rated power: 0 W – 3680 W
Energy display: 0 kWh – 999.9 kWh
Maximum bit characters for time: 9999 hours
Operating temperature: +5 °C to +40 °C
Operating humidity:
80% under +3 °C, from +31 °C to +40 °C this
value is reduced linearly to 50%
Safety class: IP20
Installation/Overvoltage category/
Measurement category:
CAT II
Note:
The energy cost meter may only be used in installations complying with Category II (CAT II) in com-
pliance with IEC 664. This means that voltage peaks of 2500 V are not exceeded. The power supply
in residential areas and company buildings normally belongs to this category.
Tolerances
Voltage: +/- 3% of the measured value
Amperage: +/- 3% of the measured value +/- 0.04 A
Output: +/- 5% of the measured value +/- 10 W
Energy: +/- 5% of the measured value +/- 0.1kWh
Attention!
The accuracy of the energy cost meter can be reduced by substantial electrical harmonic wave dis-
turbances. The accuracy returns to its normal value, however, as soon as the disturbances are
cleared.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olympia EKM 2100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olympia EKM 2100 in the language / languages: English, German as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info