OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r02 (9/12/13)
OVERVIEW
Watch, Pressure Integrated Dive Computer featuring >>
• 4 Control Buttons.
• 6 Operating Modes.
• Watch Default Time (Main or ALT).
• Watch Dual Time (Main or ALT).
• Audible Alarm with fl ashing LED.
• Digital Compass.
• Altitude Compensation.
• 15+ Menus.
• 60+ Set Selections.
• Increase/Decrease Set Values.
• up to 4 Nitrox Gas Mixes.
• up to 4 Pressure Transmitters.
• 30+ Warnings/Alarms.
• User Replaceable Battery.
INTERACTIVE CONTROL CONSOLE
The Interactive Control Console utilizes 4 control buttons that allow you to maneuver through the OCi's unique system of menus.
The buttons will be referred to as M, S, L, and A.
• Upper/Left - Mode (M) button.
• Upper/Right - Select (S) button.
• Lower/Right - Light (L) button.
• Lower/Left - Advance (A) button.
MENU SYSTEM
The Dot Matrix located in the middle of the LCD viewing area is used to display alpha numeric messages and measured values
as well as Menu type systems for selection of settings and various auxiliary functions. It also serves as the Digital Compass which
can be accessed during operation in any mode.
There are 15 Menus that include the -
• Watch Main Menu. • Set Time Menu.
• NORM Main Menu. • Set Gas Menu.
• GAUG Main Menu. • Set Alarms Menu.
• FREE Main Menu. • Set Utilities Menu.
• TECH FREE Main Menu. • Set TMT Menu.
• Compass Main Menu. • Set Compass Declination Menu.
• Log/History Menu. • Compass Reference Menu.
• Gas/TMT Switch Menu.
Each Menu has a Start (First) selection and a Stop (Last) selection. Upon entering a Menu, movement through it begins at the
Start (First) selection, then continues in a rolling manner down the screen showing selections in groups of 3 items.
• The sample at the right shows how a menu would look if all of the selections could be displayed on one screen.
Menu button action >>
M (< 2 sec) - to access Menu.
A (< 2 sec) - to step down the screen (forward) through selections.
M (< 2 sec) - to step up the screen (backward) through selections.
S (< 2 sec) - to access selection indicated by Arrow icon ( > ).
Right Arrow icon ( > ) at the left indicates the selection.
Down Arrow icon ( v ) at the right indicates that additional selections are available below (after) those shown.
Up Arrow icon ( ^ ) at the right indicates that additional selections are available above (before) those shown.
• Dual Algorithm.
• NDL Conservative Factor.
• No Deco Deep Stop.
• No Deco Safety Stop.
• Gas Switching.
• Transmitter Switching.
• Gauge Dive Run Timer.
• Depths to 330 FT/100 M.
• Tech Free Depths to 495 FT/150 M.
• Free & Tech Free Dive Run Timers.
• Free & Tech Free Countdown Timers.
• Variable Ascent Rate.
• PC Settings Upload/Data Download.
• User Upgradeable Firmware.
FREE
MAIN MENU
SEL
>
SEL TIMER
CDT SETUP
LOG/HISTORY
SET ALARMS
SET UTILITIES
OP MODE
OCi ID
Sample Menu
(all selections shown)
Selection can
be accessed.
There is a selection above.
There is a selection below.
M
A
S
L
M
A
S
L
OCi
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic OCI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic OCI in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic OCI

Oceanic OCI User Manual - German - 76 pages

Oceanic OCI User Manual - French - 76 pages

Oceanic OCI User Manual - Italian - 76 pages

Oceanic OCI User Manual - Spanish - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info