551826
2
Zoom out
Zoom in
Previous page
1/2
Next page
© 2002 Design, 2007 Doc. n.º 12-2737-r01 (8/6/07)
Botón A (arriba), botón S (lateral)
MODOS DE INMERSIÓN
[entrada al descender a 5 FT (1,5 M) durante 5 seg.]
PRINC. INMERSIÓN NORMAL
(PROF, PRESIÓN, DTR, ATR, TLBG)
PRINC. INMERSIÓN PROFUND.
(PROF, EDT, ATR)
PRINC. INMERSIÓN APNEA
(PROF, EDT, NDC, TLBG)
NORMAL
ALT 1
NORMAL
ALT 2
NORMAL
ALT 3
a la prof./hora
ajustada,
tras > 30 FT
(9 M)
A < 2 seg.
A < 2 seg.
VOLVER A
PRINC. INMERSIÓN
Prof. máx.,
EDT
- o 5 seg. para
PRINC.
INMERSIÓN
PO2, FO2,
O2BG
Temp,
Tiempo
AJUSTE
ILUMINACIÓN
VOLVER A
PRINC. SUPERF.
S 2 seg.
S 2 seg.
S 2 seg.
- o 5 seg. para
PRINC.
INMERSIÓN
Para cambiar el ajuste:
• pulse S < 2 seg. para
ver y cambiar valores
de ajuste
• pulse A < 2 seg. para
guardar el ajuste y volver
a PRINCIPAL
PROFUND.
ALT 1
PROFUND.
ALT 2
A < 2 seg.
A < 2 seg.
Temp,
Tiempo
VOLVER
A PRINC.
INMERSIÓN
A < 2 seg.
Prof. máx.,
Presión
- o 5 seg. para
PRINC. INMERSIÓN
CDT APNEA
(ON/OFF)
APNEA
ALT
A < 2
seg.
Temp,
Tiempo
A 2 seg.
S < 2 seg.
(alternar)
- o 5 seg. para
PRINC. INMERSIÓN
- o 5 seg. para
PRINC. INMERSIÓN
VOLVER A
PRINC. INMERSIÓN
A < 2
seg.
AJUSTE
ILUMINACIÓN
S 2 seg.
VOLVER A
PRINC. SUPERF.
S 2 seg.
NIVEL
- o 30 seg.
para PRINC.
INMERSIÓN
Para cambiar el ajuste:
• pulse S < 2 seg. para
ver los valores de ajuste
• pulse A para guardar
el ajuste y volver a
PRINCIPAL
Advertencia de batería baja <= 2,75 voltios (icono encendido)
Alarma de batería baja <= 2,50 voltios (apagado de la unidad)
Batería: 3 voltios, CR2, Litio
Ajuste automático altitud NDL de 2.000 a 14.000 ft
Factor de seguridad (NDL = siguiente > 3.000 ft)
PARADA
SEGURIDAD
(si hay)
A < 2 seg.
- o 5 seg. para
PRINC.
INMERSIÓN
ALARMAS INMERSIÓN NORMAL/PROFUND. (10 seg.)
• • pulse A (2 seg.) para responder/silenciar
• Velocidad ascenso > 60 FPM (18 MPM) cuando > 60 FT (18 M)
• Velocidad ascenso > 30 FPM (9 MPM) cuando <= 60 FT (18 M)
• Profundidad => Valor de ajuste
• Profundidad => 330 FT (99,9 M)
• Tiempo restante de aire bajo
• Tiempo restante de inmersión bajo
• Pérdida de conexión
• Presión de retorno y llegada
• Tiempo transcurrido de inmersión excesivo
• Entrada en descompresión (sólo NOR)
• Por encima de la parada de descompresión (sólo NOR)
• > 60 FT (18 M) parada de descompresión obligatoria (sólo NOR)
• PO2 alta (sólo NOR)
• O2 alto (sólo NOR)
- o 30 seg.
para PRINC.
INMERSIÓN
ILUMINACIÓN (todos los modos) • • pulsar/soltar S (< 2 seg.) para alternar entre ON/OFF
MODO SUPERFICIE • • entrada a 2 FT (0,6 M) durante 1 seg.
- o 5 seg. para
PRINC. INMERSIÓN
ALARMAS INMERSIÓN APNEA • • no se puede responder/silenciar
• Tiempo de inmersión transcurrido • 3 avisos (repetidos cada 30 seg.)
• Profundidad 1/2/3 => Valor de ajuste • 3 avisos/3 veces
• Precaución TLBG (4 segmentos) • 3 avisos/3 veces
• Violación (entrada en descompresión) • 3 avisos/3 veces
• CDT = 0:00 • 3 avisos/3 veces
A < 2 seg.
NIVEL
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oceanic DataMask HUD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oceanic DataMask HUD in the language / languages: Spanish as an attachment in your email.

The manual is 0,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oceanic DataMask HUD

Oceanic DataMask HUD User Manual - English - 148 pages

Oceanic DataMask HUD Additional guide - German - 2 pages

Oceanic DataMask HUD User Manual - German - 148 pages

Oceanic DataMask HUD Additional guide - French - 2 pages

Oceanic DataMask HUD User Manual - Italian - 148 pages

Oceanic DataMask HUD User Manual - Spanish - 148 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info