718524
15
Zoom out
Zoom in
Previous page
1/18
Next page
EN
If the screen displays an error code “Ex”, please refer to the table below.
E5 error code
- Reset thermal cutout
(1) Cut off power of pump
(2) Insert the stopper caps onto the inlet and outlet on the pool inner wall
(3) Disassemble pump, turn over the pump.
(4) Locate the small hole marked “RESET” on the bottom of pump. Then, inset a small stick (It should be less than Ø0.9cm,
length is longer than 10cm) into the hole, press down, you can hear “ping”, the reset is successful.
(5) Then, connect pump with pool again. Take off the stopper on the inner pool and repeat the previous outlined steps to use
your SPA.
6.2. Error code
Code Situation Problem Causes Solutions
E1
Not heating Not
heating properly.
Wrong temperature
control sensor.
Temperature control sensor short
circuit or open circuit.
Contact NetSpa service center.
E2
Not heating
properly.
Wrong temperature
control sensor.
Temperature control sensor short
circuit or open circuit.
Contact NetSpa service center.
E3
Not heating
properly.
High water tempera-
ture indicator.
The lled water is over 45°C
(113°F).
·Cut off the power, make sure the pool
water is between 2°C~44°C (36°F~111°F)
·If this does not solve the problem, contact
NetSpa service center.
E4
All functions do
not work, buzzing
warn.
Low water tempera-
ture indicator.
The pool water is lower than 2°C
(36°F).
·Cut off the power, make sure the pool
water is between 2°C~44°C (36°F~111°F)
·If this does not solve the problem, contact
NetSpa service center.
E5
All functions do
not work, buzzing
warn.
High water tempera-
ture indicator.
The lled water is over 50°C
(122°F).
·Cut off the power, turn to qualied
electrician to reset the thermal cutout
described in next paragraph. If this does
not solve the problem, contact NetSpa
service center.
E6
Not heating and
ltering properly.
Buzzing warns.
Water pressure is
not big enough to
activate heating.
·Inlet or outlet on inner wall are
blocked.
·Filter cartridge is too dirty.
·Pool water does not reach mini-
mum water level.
·Do not release air from pump
Pump is wrong”
·Clean inlet and outlet
·Clean or replace lter cartridge
·Add water to reach water level
·Do air release as outlined again
·If this does not solve the problem, contact
NetSpa service center.
E7
All functions do
not work, buzzing
warn.
Dry-run heater.
Heating at no water situation,
system shut down automatically
Contact NetSpa service center.
15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Netspa Vita Premium at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Netspa Vita Premium in the language / languages: English as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Netspa Vita Premium

Netspa Vita Premium Usermanual and installation guide - German - 18 pages

Netspa Vita Premium Usermanual and installation guide - French - 18 pages

Netspa Vita Premium Usermanual and installation guide - Italian - 18 pages

Netspa Vita Premium Usermanual and installation guide - Spanish - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info