Electric Underfloor Heating04
2.0 Preparation
l
A MYSON mat system.
l
Flexible tile adhesive or levelling/screed and
grout suitable for floor heating.
l
Flexible cement and cement gun for expansion
joints along the walls.
l
Approx. 2m flexible electrical piping (16mm).
l
Plastic glue comb with approx. 6mm teeth.
l
Electrical junction box (min 40mm deep).
l
Power outlet with RCD 30mA.
l
Adhesive or double sided tape (for screeded
floors).
2.2 Preparation: Placing the Thermostat
Determine where the thermostat is to be placed.
Place a standard electrical junction box*, preferably
at a height of 1.5m for ease of operation. Grind/cut
the necessary grooves (fig 1) and mount the
junction box and suitable sheathing/conduit to
allow plastering after installation.
Cut a groove in the floor for the floor sensor pipe
20mm deep (fig 2). Feed the sensor through the
flexible pipe (fig 3). The sensor must always
remain in the flexible pipe. Cap the end of the
pipe (fig 4) to avoid the sensor getting stuck
during installation. If the sensor ever needs to be
replaced it can then easily be removed.
Ensure that the surface where the mat is worked
on is flat, clean, and free of dust and grease. In
larger spaces place the edge strips/expansion
joints along the wall.
2.1 Preparation: Necessary Materials
Check the contents of the box before starting.
A complete set will consist of:
l
Heating mat with connecting wire
l
Control card
l
Digital clock thermostat incl. floor sensor
l
Flexible sensor pipe
l
Multimeter
l
Installation manual
PLEASE NOTE: Never place the sensor in the vicinity of a hidden radiator pipe and never install it
passing under a heating cable. The sensor MUST always remain in the flexible pipe.
Fig. 1 Fig. 2
Fig. 3 Fig. 4
* See Section 7.0 Electrical Connection.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Myson ELECTRIC UNDERFLOOR HEATING at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Myson ELECTRIC UNDERFLOOR HEATING in the language / languages: English as an attachment in your email.

The manual is 4,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info