INSTRUCTION MANUAL AIR QUALITY SENSORS GS 4X.00 KNX
HUGO MÜLLER GMBH & CO KG, STURMBÜHLSTR. 145-149, 78054 VS-SC
HWENNINGEN
SAFETY INSTRUCTIONS AND BASICS
G
S 40.00 knx
GS 41.00 knx
Technical data
Safety instructions / Intended use
Power supply:
Bus current:
Via KNX bus voltage
< 10 mA
CAUTION! DANGER OF FIRE AND ELECTRIC SHOCK!
!!!Installation and assembly of electrical equipment must be carried out only by a skilled person!!!
Bus system :
KNX
Connect only to suitable supply voltage [KNX bus voltage (nominal voltage 29V)].
Warranty void if housing opened by unauthorized person!
The electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if external influences
exceed
certain limits!
Installation and assembly of electrical equipment must be in accordance with national building, electrical and safety codes!
Defective devices / sensors have to be put out of service immediately!
Observe the regulations and instructions in the ZVEI/ZVEH handbook (building system technology). Especially the professional
installation of
the bus lines and the professional installation and start-up of KNX devices must be observed!
The device fits for the particular use of the following tasks: monitoring of the air quality in building systems technology (schools,
offices,
hotels, conference venue etc.), data transfer and regulation via bus system.
The device is intended for use in accordance with the defined technical data.
Operate the device exclusively in a dry room!
The device is not qualified for security relevant tasks such as emergency doors, fire protection equipment, fermenting cellars etc.
Sensors:
CO
2
, relative humidity, temperature,
atmospheric pressure
Manual operation (GS 41.00 knx):
Manual adjustment of set-point temperature
±3° (increment 0.5°)
Measuring range CO2 concentration:
39010.000 ppm
Measuring range relative humidity:
0–100%
Measuring range temperature:
0–50°C
Measuring range atmospheric pressure:
absolute atmospheric pressure
Permitted ambient temperature :
-0°…+50°C
Housing:
self-extinguishing thermoplastic
Mounting:
Wall
Type of connection :
Push-in connector
Type of protection :
IP 20 to DIN EN 60529
Class of protection:
III when installed according to regulations
Source of interference
Inappropriate use / disposal
Operation of GS 41.00 knx
The measurement results of the device can
be negatively influenced by external factors
.
Possible sources of interference are:
■ Draught and air movement: e.g. through
windows, doors, convection, heating and
people
■ Warming and cooling: e.g. sunlight or
mounting on an outside wall
■ Heat sources: close to installed electrical
consumers e.g. dimmers
■ Vibrations or shocks, which the unites are
or were subjected to
■ Pollution due to colors, wallpaper paste,
dust e.g. at renovation work
■ Organic solvents or their vapours: e.g.
detergents
■ Plasticizers from stickers and packaging:
e.g. bubble wrap or polystyrene
The device is not intended for use of unauthorized constructional
alterations, repairs and security relevant tasks
The device is not intended for use in outdoor areas and wet rooms
The device is not qualified for security relevant tasks The controlling of
the device is only for the observation and regulation of the air quality
The inappropriate use of the device can cause damage to property and
persons
The device has to be disposed in an environmentally friendly manner
according to the current electrical codes!
Set-point temperature
manually adjustable
via touch-area
(adjustment range
±3°; increment 0.5°).
Display with LEDs.
ASSEMBLY
Assembly
Disconnect device from power supply for wiring and installation
purposes! Check power supply is disconnected!
Attention! You have to check and consider the safety instructions above!
This device is suitable for wall mounting or for mounting on a flush-mounting
box.
The device should not be exposed to dusty environment.
Ensure that no dust get inside of this device.
After initial startup, the device requires up to 5 minutes until the first correct
measurement is possible
STEP 1: Open the device at the bottom and remove the front cover!
STEP 2: Mount the rear cover to the wall or on a flush-mounting box
(see installation note)
STEP 3: Wire the device. Press the „programming button to put the device
into operation.
STEP 4: After completing the installation the front cover must be reattached!
Installation note: Make sure that no wires are pinched or squeezed when installing the cover. The mounting of the device on a flush-mounting box is recommended for easier handling and wiring.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Muller GS 40.00 knx at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Muller GS 40.00 knx in the language / languages: English, German as an attachment in your email.

The manual is 0,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Muller GS 40.00 knx

Muller GS 40.00 knx Installation Guide - English - 28 pages

Muller GS 40.00 knx Installation Guide - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info