587215
18
Zoom out
Zoom in
Previous page
1/22
Next page
17
HOW TO MAINTAIN
Ceiling cassette −4 way Compact (600 x 600 mm)− (FDTC)
1. Slide the inlet grille levers in the direction of the
arrow (
), and open it downwards.
2. Turn the inlet grille stopper.
3. Pull the filter toward you.
4. When the filter is put in place, insert the filter into
the hooks on the inlet grille, and be sure to return
the stopper to its original position.
5. When putting the inlet grille back in place, slide the
levers in the opposite direction and check to be
sure that the grille does not come open.
Hooks
Hooks
Stopper
HOW TO MAINTAIN
Air filter is attached when the air conditioner is installed, so consult your dealer about how to remove or clean it.
Duct connected −High static pressure− (FDU)
Duct connected −Middle static pressure− (FDUM)
Duct connected (Ultra thin) −Low static pressure− (FDQS)
Duct connected −Compact & Flexible− (FDUH)
Duct connected −High static pressure Out door Air processing unit (FDU -F)
Duct connected −Low static pressure− (FDUT)
Floor standing -2way- (FDFW)
<How to open, close the inlet panel>
Open
Place fingers at the recesses on both sides of the panel
and pull down the panel forward so that it will be open by
about 15°.
Close
Push both ends evenly and press further lightly at the
center.
Ceiling cassette −1 way− (FDTS)
1. Slide the lever of the suction grille in the arrow ( ) direction
to open the grille.
2. While light pushing up, remove the filter from the tabs at the
left and righit, and pull towards the front
.
Ceiling cassette −1 way compact− (FDTQ)
1. Slide the lever of the suction grille in the arrow ( ) direction
to open the grille.
2. While light pushing up, remove the filter from the tabs at the
left and righit, and pull towards the front
.
Air filter
Ta b
Suction grille
Tabs
Air filter
Ta b
Suction grille
Tabs
<How to remove, install the inlet panel>
Remove
When removing the panel for internal cleaning or others,
open the panel, remove the string and then pull it forward.
Install
Secure the upper edge of the panel by lightly pushing it
in, place the string as illustrated and then close the panel.
<How to remove, install the filter>
Remove
1. Pull up the air inlet panel forwards.
2. Lightly hold the knobs at the both sides and lift a little to
remove the panel forward.
Install
1.
Hold firmly the filter at the both sides as shown at right
and insert securely.
2.
Close the air inlet panel.
Floor standing (with casing) (FDFL)
Remove the front panel and pull the air filter out from the
bottom of the unit.
Floor standing (without casing) (FDFU)
Pull the air filter out from the bottom of the unit.
Wall mounted (FDK)
1.
Pull up the suction grille forward.
Hold the concave sections at both the righit and left side
with your hands and pull the suction grille forward.
It stops while being open at about 60
°
.
2.
Lightly hold the handle of the air filter , slightly lift it upward,
and then pull it out forward.
When mounting, press the lever forward untill it snaps.
When morrting, snab the filter into the tabs of inlet grille.
Ceiling suspended (FDE)
1. Slide the lever of the inlet grille backward ( direction) and
open it downwards.
2. Pressing the inlet grille, press the filter to remove it from the
tab and pull it
downwards.
Air filter
tabs
Ceiling cassette −2 way− (FDTW)
1. Push one side of the inlet panel (pin A side) upward.
2. Disengage the panel from pin A.
3. Disengage the panel from the pin B and remove the panel.
4. Press the air filter and turn the stopper to remove the air
filter.
e
Disengage the pin B side.
c Push the pin A side upward.
d Disengage the pin A side.
Pin B Pin A
Panel
Stopper
Number of stoppers
FDTW 28 - 71 6pc.
FDTW 90-140 10pc.
Caution
Install the air filter in the correct order.
Tu r n
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi FDQS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi FDQS in the language / languages: English as an attachment in your email.

The manual is 10,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mitsubishi FDQS

Mitsubishi FDQS User Manual - German - 22 pages

Mitsubishi FDQS User Manual - Dutch - pages

Mitsubishi FDQS User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info