588105
4
Zoom out
Zoom in
Previous page
1/8
Next page
55
66
OPERATING INSTRUCTIONS
8. Connecting pipe
9. Connecting cable
10. Stop valve
Outdoor unit
Outdoor unit
NOTE: The display on the indoor unit
you purchased may look like one of
the following:
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver(inside)
7. Display panel
Indoor unit
Indoor unit
Special functions
4
3
5
2
6
1
9
10
8
7
RUN indication lamp
This lamp illuminates when the air
conditioner is in operation.
FRESH indication lamp(optional function)
This lamp illuminates when Clean
Air feature is activated.
AUTO indication lamp
Lights up under auto operation..
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(Applicable to cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm
air control feature is activated in heating
operation.
Temperature indicator
Displays the temperature settings when the
air conditioner is operational.
Displays the malfunction code.
A
B
C
fresh defrost run timer
fresh defrost run timer
auto defrost run timer
NAMES OF PARTS
Indication lamp
Indication lamp
NOTE:
All the pictures in this manual are for
explanation purposes only. The actual shape
of the indoor unit you purchased may be slight
different on front panel and display window.The
actual shape shall prevail.
Names of parts
Special functions
This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific
configuration of the model). With the anions generated by Ionizer, the air circulation of the air
conditioner fills the room with refreshing, natural and healthy air. The Plasma Dust Collector
generates a high voltage ionization zone, through which the air is converted to plasma. Inside
the air most of the dust, smoke, and pollen particles are captured by the electrostatic filter.
CLEAN AIR function(optional):
Vertical swing function(optional):
After the air conditioner starts up, users can control the vertical louver swing by the remote
controller.
SELF CLEAN function(optional):
Function used after the Shut Down of cooling operation to clean the Evaporator
and keep it as fresh for the next operation.
The unit will operate as following sequence : FAN ONLY mode at Low fan speed--Heating
operation with LOW fan speed(applicable to cooling & heating modles only) ---FAN ONLY
operation--Stop Operation---Turn off.
Note:
This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode.
Before select the function, it is recommended to run the air conditioner under Cooling
operation for about half an hour. Once the Self Clean function is activated, all TIMER
setting will be cancelled.
During Self Clean operation, when press the SELF CLEAN button on the remote
controller again will stop the operation and turn off the unit automatically.
Louver Angle Memory Function(optional):
Within the scope of safety angle, it will memorize the open angle of horizontal louver.
If it exceeds, it will memorize the boundry of safety angle. In the following circumstances,
it will return to standard angle: 1) pressing the manual switch, 2)unplug and then plug
in the machine. So we strongly suggest that the open angle of the horizontal louver should
not be set too small, in case the condensed water forms and drops from the horizontal louver.
Refrigerant Leakage Detection (optional):
With this new technology, the dipsplay area will appear EC and the indication lamps
continue flashing when the outdoor unit detects refrigerant leakage.
,
,
Anti-mildew function(optional):
When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue
operating for about 7-10 minutes (depending on models) at LOW fan speed. If turns off on
HEAT mode, the unit will continue operating for about 30 seconds at LOW fan speed. This will
help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea Oasis MSOW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea Oasis MSOW in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea Oasis MSOW

Midea Oasis MSOW Installation Guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info