OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Special functions
Improving the quality of indoor air is one
of the purposes of an air conditioner.
This air conditioner is equipped with
ionizer or Plasma Dust Collector(model
dependent). With the anions generated
by Ionizer, the air circulation of the air
conditioner fills the room with refreshing,
natural and healthy air. The Plasma Dust
Collector generates a high voltage
ionization zone, through which the air is
converted to plasma. Inside the air most
of the dust, smoke, and pollen particles
are captured by the electrostatic filter.
CLEAN AIR function(Optional)
Airborne bacteria use the moisture on the
indoor heat exchanger to grow. Regular
drying of the exchanger prevents this
growth. By simply pressing the SELF
CLEAN button, the system will automatically
manage the process. This cleaning action
may be done as frequently as desired.
For cooling models, only the indoor fan is
active in low speed for 30 minutes and the
unit turns off automatically.
For cooling & heating models, the unit will
operate as in the following sequence :
FAN mode at Low fan speed--Heating
operation with LOW fan speed ---FAN
operation--Stop Operation---Turn off.
Note:
This function is only activated in COOLING
or DRY mode.
Before activation the air conditioner, it is
recommended to run the air conditioner
under cooling operation for about 30
minutes.
Pressing the SELF CLEAN or ON/OFF
button again during the cleaning cycle will
cancel the operation and turn the unit off.
SELF CLEAN function(Optional)
Refrigerant Leakage Detection (Optional)
When refrigerant leakage is detected,
the indoor unit will display EC code or
flash LEDs(model dependent).
Anti-mildew function(Optional)
Anto-restart function(Optional)
When turns off the unit on COOL, DRY,
AUTO (Cool) mode, the air conditioner
will continue operating for about 10
minutes (depending on models) with soft
wind.This will help to dry up the
condensed water inside the evaporator,
and prevent the mildew growth. Under
Anti-mildew operation, do not restart the
air conditioner until the unit is completely
off.
In event of power interruption such as a
blackout, the air conditioner stops once.
But it restarts automatically and performs
previous operation when the power supply
is resumed.
,
,
Louver Angle Memory Function(optional):
Within the scope of safety angle, the
horizontal louver angle is memoriesed
and will return to the position last selected
by user. If it exceeds, it will memorize the
boundry of safety angle. This will not
happen when Turbo or manual control
buttons are pressed or after a power
interruption. So we strongly suggest that
the open angle of the horizontal louver
should not be set too small, in case the
condensed water forms and drips from
the horizontal louver.
After 240 hours of operation, the indoor
display window will display and flash CL ,
this feature is a reminder to clean the Air
Filter for more efficient operation. After 15
seconds, the system will revert back to the
previous display again. When the CL
indicator appears and flashes, please
press the LED button on remote controller
for 4 times or press the Manual control
button for 3 or more times to clear the
registered hours, otherwise the CL
indicator will display and flash again for
another 15 seconds at the next time of
tarting the unit.
After 2880 hours of operation, the indoor
display window will display and flash nF ,
this feature is a reminder to replace the Air
Filter for more efficient operation. After 15
seconds, the system will revert back to the
previous display again. When the nF
indicator appears and flashes, please
press the LED button on remote controller
for 4 times or press the Manual control
button for 3 or more times to clear the
registered hours, otherwise the nF
indicator will display and flash again for
another 15 seconds at the next time of
starting the unit.
Air Filter Reminding Function(optioal)
WIFI Control Function(optional)
For the unit with WIFI control function,
connect the WIFI module and
communication module with display
board, so the unit can be controlled
either by remote controller or by
mobile telephone.
Mute operation(optional)
Press the LED button on the remote
controller can turn off the indoor screen
display, and also turn off the Air
conditioner buzzer, which create a
comfortable and quiet environment.
Cleaning filter reminding function:
Replacing filter reminding function:
,
,
,
,
,
,
,
,
,
,
,
,
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea MISSION Serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea MISSION Serie in the language / languages: English as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea MISSION Serie

Midea MISSION Serie Installation Guide - English - 8 pages

Midea MISSION Serie Installation Guide - German - 8 pages

Midea MISSION Serie User Manual - German - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info