Preface
The WatchBP Ofce Central has been validated against simultaneous recorded intra-arterial blood pressure measurement, which is the gold standard for
validation of central blood pressure measurement, and showed extreme high accuracy
1
. The WatchBP central has passed the validation protocol of the BHS
for accuracy in blood pressure measurement (A/A) and is equipped with innovative screening tools such as:
An implemented atrial brillation (Ab) detection system that has proven excellent accuracy
2, 3
and is ofcially recommendation by the National Institute of
Clinical health and Excellence (NICE) in the UK
4
.
Two arm cuffs that allow simultaneous blood pressure measurement of both arms for accurate determination of inter-arm blood pressure differences
5, 6
.
This mode is highly supported by the latest ESH guidelines (2013) stating that Inter-arm difference in blood pressure is only meaningful when obtained from
simultaneous arm blood pressure measurement
7
.
Ankle-brachial index (ABI) performance that is validated against Doppler for accuracy with positive results and additionally showed that the assessment led
to a signicant time reduction as compared to Doppler
8
. Finally, the automated calculation of the ABI value guarantees uniformity and prevents errors due to
registration and calculation failures
9
.
1. Cheng, H.M., et al., Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Ofce Central. Am J Hypertens. 2013. 26: 42-50.
2. Stergiou, G.S., et al., Diagnostic accuracy of a home blood pressure monitor to detect atrial brillation. J Hum Hypertens, 2009. 23: 654-8.
3. Wiesel, J., et al., Detection of atrial brillation using a modied microlife blood pressure monitor. Am J Hypertens, 2009. 22: 848-52.
4. NICE, WatchBP Home A for opportunistically detecting atrial brillation during diagnosis and monitoring of hypertension. http://guidance.nice.org.uk/MTG13, 2013.
5. Lohmann, F.W., et al., Interarm differences in blood pressure should be determined by measuring both arms simultaneously with an automatic oscillometric device. Blood Press Monit, 2011. 16: 37-42.
6. Stergiou, G.S., et al., Automated device that complies with current guidelines for ofce blood pressure measurement: design and pilot application study of the Microlife WatchBP Ofce device. Blood Press
Monit, 2008. 13: 231-5.
7. Mancia, G., et al., 2013 ESH/ESC Guidelines for the management of arterial hypertension: The Task Force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of
the European Society of Cardiology (ESC). J of Hypertens. 2013, 31:1281–1357.
8. Kollias, A., et al., Automated determination of the ankle-brachial index using an oscillometric blood pressure monitor: validation vs. Doppler measurement and cardiovascular risk factor prole. Hypertens Res,
2011. 34: 825-30.
9. Verberk, W.J., et al., Automated oscillometric determination of the ankle-brachial index: a systematic review and meta-analysis. Hypertens Res, 2012. 35: 883-91.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Microlife WatchBP Office Central at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Microlife WatchBP Office Central in the language / languages: English as an attachment in your email.

The manual is 2,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Microlife WatchBP Office Central

Microlife WatchBP Office Central User Manual - French - 41 pages

Microlife WatchBP Office Central User Manual - Spanish - 41 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info