3BP A130
EN
How do I evaluate my blood pressure?
The higher value is the one that determines the evaluation.
Example: a readout value between 150/85 or 120/98 mmHg indi-
cates «blood pressure too high».
2. Using the Instrument for the First Time
Activating the fitted batteries
Pull out the protective strip projecting from the battery compartment
7
.
Setting the date and time
Changing the language
You can change the language by using the following procedure:
Adjusting the volume
Use the volume control 6 to adjust the volume of the speaker.
Selecting the correct cuff
Microlife offers different cuff sizes. Select the cuff size to match
the circumference of your upper arms (measured by close fitting in
the centre of the upper arm).
3. Taking a Blood Pressure Measurement using this
Instrument
If you suffer from an irregular heartbeat, measurements taken
with this instrument should only be evaluated after consultation
with your doctor.
The pulse display is not suitable for checking the
frequency of heart pacemakers!
Table for classifying blood pressure values in adults in accordance
with the World Health Organisation (WHO) in 2003. Data in mmHg.
Range Systolic Diastolic Recommendation
blood pressure
too low
z 100 z 60 Consult your doctor
1. blood pressure
optimum
100 - 120 60 - 80 Self-check
2. blood pressure
normal
120 - 130 80 - 85 Self-check
3. blood pressure
slightly high
130 - 140 85 - 90 Consult your doctor
4. blood pressure
too high
140 - 160 90 - 100 Seek medical advice
5. blood pressure
far too high
160 - 180 100 - 110 Seek medical advice
6. blood pressure
dangerously
high
180 y 110 y Urgently seek
medical advice!
1. After the new batteries are fitted, the year number flashes in
the display. You can set the year by pressing the M-button AT.
To confirm and then set the month, press the time button AK.
2. You can now set the month using the M-button. Press the time
button to confirm and then set the day.
3. Please follow the instructions above to set the day, hour and
minutes.
4. Once you have set the minutes and pressed the time button, the
date and time are set and the time is displayed.
5. If you want to change the date and time, press and hold the time
button down for approx. 3 seconds until the year number starts
to flash. Now you can enter the new values as described above.
1. While the device is switched off keep the ON/OFF button 1
pressed until you see the letters «LAn» on the LCD.
2. Now you can change the language by continuously pressing the
M-button AT:
1=English, 2=Greek, 3=Italian, 4=Turkish, 5=Arabic, 6=Farsi.
3. Confirm the selection by pressing the ON/OFF button 1.
Cuff size for circumference of upper arm
S 17 - 22 cm (6.75 - 8.75 inches)
M 22 - 32 cm (8.75 - 12.5 inches)
L 32 - 42 cm (12.5 - 16.5 inches)
M - L 22 - 42 cm (8.75 - 16.5 inches)
)
Optional preformed cuffs «Easy» are available.
)
Only use Microlife cuffs.
X
Contact Microlife Service if the enclosed cuff 8 does not fit.
X
Connect the cuff to the instrument by inserting the cuff
connector 9 into the cuff socket 4 as far as it will go.
Checklist for taking a reliable measurement
1. Avoid activity, eating or smoking immediately before the
measurement.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Microlife BP A130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Microlife BP A130 in the language / languages: English, Italian, Turkish as an attachment in your email.

The manual is 3,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info