MI 3310 / MI 3310A SigmaGT Appendix C – Country notes
134
Pre-programmed autotest sequences table (cont’d)
Autotest shortcut code
11 12 13 14
Description
KL1 30mA
PRCD
KL1 3L+N(VL
2E)
KL2
LEKSTROOM
KL1
LEKSTROOMTANG
Visual test
Earth bond
Output 200 mA 200 mA
200 mA
Limit
0.30 0.30
0.30
Time 5 s 5 s
5 s
Insulation
Output 500 V 500 V
Limit
1.00 M 1.00 M
Time 5 s 5 s
Insulation
(probe)
Output
Limit
Time
Sub leakage
Output
Limit
Time
Sub leakage
(probe)
Output
Limit
Time
Differential
leakage
Output
230 V
Limit
0.5 mA
Time
10 s
Touch leakage
Output
Limit
Time
Power
Output
230 V
Limit
Time
10 s
TRMS clamp
current
Output
Enkel
Limit
0.5 mA
Time
5 s
Polarity test
RCD test
Mode Single
Type AC
Id RCD 30 mA
Multi 1
Fase (+)
Test PRCD
Note:
When polarity test in enabled in autotest sequence then earth bond resistance is
performed between IEC test connector (PE terminal) and test socket (PE
terminal). If polarity test is disabled in autotest sequence, earth bond test is
perfomed between EB/S test probe and test socket (PE terminal).
134


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel SigmaGT MI 3310A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel SigmaGT MI 3310A in the language / languages: English as an attachment in your email.

The manual is 1,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel SigmaGT MI 3310A

Metrel SigmaGT MI 3310A User Manual - German - 122 pages

Metrel SigmaGT MI 3310A User Manual - Dutch - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info