MI 3109 EurotestPV Lite Appendix E – PV measurements – calculated values
73
Depending on temperature criterion for PASS is:
If Tamb < 25 °C or Tcell < 40 °C => η2>0.85
If Tamb > 25 °C or Tcell > 40 °C => η2>(1-ηPV-0.08),
where ηPV is calculated depending on type of temperature being measured as
or
,
where NOCT is nominal operating temperature of the cell (data supplied by the
panels manufacturer) and γ is coeff. of temperature of power characteristic of PV
module (inserted value from 0,01 to 0,99) (data supplied by the panels
manufacturer).
NOCT nominal operating temperature of the cell (data supplied by the panels
manufacturer)
γ coeff. of temperature of power characteristic of PV module (inserted
value from 0,01 to 0,99) (data supplied by the panels manufacturer)
2. inverter:
A
C
D
C
P
P
.
Calculation of conversion efficiency with comparison of STC and measured-
corrected values
(U, I (AC, DC), phase, Irrstc, Tstc, Pnom, Irr, Tcell, Rs, α, β, Isc, M, N)
Panel:
Measured U and I are corrected to STC conditions:
11
111
(1) ()
() ()
STC
STC SC STC
STC S STC STC
Irr
III NTT
Irr
M
UU RIIMTT
N
 

,
where I1 and U1 are measured direct current and voltage at panel, Isc is measured short-
circuit current of panel, IrrSTC is irradiance at STC, Irr is measured irradiance, α and β
are the current and voltage temperature coeff. off panel, TSTC is temperature at STC, T1
is measured temperature, Rs is serial resistance of panel, M is number of modules in
serial and N is number of modules in parallel.
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3109 - Eurotest PV Lite at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3109 - Eurotest PV Lite in the language / languages: English as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3109 - Eurotest PV Lite

Metrel MI 3109 - Eurotest PV Lite Quick start guide - Dutch - 68 pages

Metrel MI 3109 - Eurotest PV Lite User Manual - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info