776296
123
Zoom out
Zoom in
Previous page
1/123
Next page
MI 3108 EurotestPV Appendix E PV measurements calculated values
123
Conversion efficiency:
1. inverter:
AC
DC
P
P
Insulation measurements of PV modules and strings
The first insulation method described in the standard IEC 62446 results in two values:
ROC+ insulation resistance between positive output and earth
ROC- insulation resistance between negative output and earth
The second method described in the standard returns only one value:
RSC insulation resistance between short circuit outputs and earth
To get comparable results both values of the first method must be converted to a single
value result. This can be done using the bellow equation, which is based on the
electrical substitute model of PV modules and returns the same or close value to the
insulation resistance measured by the second method.
To get accurate results care must be taken, when performing insulation measurements.
PV module or string can have a significant capacitive nature therefore the duration of
the measurement must be long enough, that the result is stable. Therefore the user has
to set up the duration of the measurement, which can be up to one minute. If the
measurement time is too short and the displayed value is not stable the final result must
be treated only as informational.
123


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3108 - Eurotest PV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3108 - Eurotest PV in the language / languages: English as an attachment in your email.

The manual is 3.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3108 - Eurotest PV

Metrel MI 3108 - Eurotest PV User Manual - German - 136 pages

Metrel MI 3108 - Eurotest PV User Manual - Dutch - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info