610027
5
Zoom out
Zoom in
Previous page
1/17
Next page
6 7
The underwater fl oodlights UWL 1275/Tec and UWL 12100/Tec are designed for the use in fountains and
garden ponds. They operate on the safe 12 V low voltage.
Transformer
The supply of the underwater fl oodlight with 12 volts low voltage has to be done with a safety-trans-
former according to VDE 0570.
This transformer also has to correspond to the conditions.
The transformer should be run only in a water-protected area!
The connection box should be at least 2 m away from the edge of the garden pond. (See fi g.1)
Caution! The transformer heats up during use.
To ensure adequate cooling, the transformer should not be installed in a poorly ventilated housing.
Supply connections
For the needed circuit lengths between the transformers and the underwater fl oodlights as well as their
amount, the required circuit cross-section areas have to be calculated!
The supply connections have to be of the type H07RN-F. They have to be suitable for the submersible use.
The mounted cable screwing allow a cable-diameter of 11 mm to max. 15mm. The supplied porcelain-clamp
ts with a max. circuit cross-section area of 10 mm².
Do not carry, hang or pull by the connection cord.
Long, hanging supply connections have to be saved separately to avoid a loosening of the transformer or
the fl oodlight!
Operation and Installation (See fi g.1)
For the installation and the using of the underwater fl oodlight, the actual national safety rules have to be
preserved. Please consult a licensed electrician.
The lights with 75 and 100 watts can be used underwater and above water. When using the lights
outside the water, a minimum distance of 50 cm (20“) to infl ammable objects must be maintained.
Attention! The coloured discs can be used only submerged.
There is the danger that the coloured discs will melt.
Max. depth 4 m! IP 68 4 m
You can fasten the underwater fl oodlight
- directly on a bracket using the lash on the housing.
- with the pedestal (12) on walls, fl agstones, etc.
- with the base plate Ø 153 and weighted down by rocks anywhere in your pond, without mounting-screws.
(rf. fi g. 3)
Depending on scope of delivery!
Changing the lamp (See fi g. 2)
As a replacement, one may use all commercial halogen incandescent lamps 12 V/75 W or 12 V/100 W
socket GY 6,35.
1. Pull out mains plug and secure against reclosing.
2. Take the complete fl oodlight out of the water and leave it to dry off.
3. Loosen the screws (5) by means of a cross-point screwdriver and remove them.
4. Remove the ring (3) from the housing (1).
5. Glass (4) and refl ector (8) are clasped with the sealing ring (2).
6. Touch the sealing ring (2) at one point and take it, together with the glass (4) and refl ector (8) out of the
casing (1).
7. Touch the sealing ring (2) at one point and remove it by pulling it over the glass (4).
8. Caution! Do not get the refl ector (8) soiled inside and do not touch it with bare hands!
9. Wash the glass (4) and the sealing ring (2) with clean water and dry them.
10. Take the halogen incandescent lamp (9) out of the refl ector (8) and the socket (11).
11. Caution! Do not touch the new halogen incandescent lamp with bare hands. If there are accidental
ngerprints, clean it with alcohol before switching-on.
12. Replace the halogen incandescent lamp (9) by inserting the 2 pins into the corresponding holes of the
socket (11).
Caution! If pushing-in requires a lot of strength, be careful! If the glass breaks, there is the danger of
injury.
13. Test the new halogen incandescent lamp for proper functioning by putting the plug into the socket for a
short time.
14. Re-assemble the fl oodlight in the reverse order.
15. Place the clean glass (4) on the middle of the refl ector (8).
16. Put the sealing ring (2) around the glass (4) and refl ector (8). The lower big lip of the sealing ring (2) is
placed under the refl ector (8), whereas the upper small lip is put on the glass (4).
GB
17. Press the sealing ring (2), together with glass (4) and refl ector (8), into the casing (1). Ensure that the
sealing ring (2) is positioned properly.
18. Fit the ring (3) onto the casing (1) in such a way that the bores of the fi tting plates are arranged one
above the other.
19. Put the screws (5) t hrough the bores from above and tighten them all uniformly with a cross-point
screwdriver.
Guarantee conditions
This device is warranted for 24 months, (lamp excluded), from the date of delivery. Proof of purchase is
required. Defects in material or workmanship will be repaired or replaced at our discretion and free of charge
during the warranty period.
Damages resulting from faulty installation or operation, calcium deposits, inadequate care, frost, normal
wear, or unauthorized repair attempts are not covered under the warranty.
Modifi cations to the device, such as separating the mains connection lines or the mains connector, invalidate
the warranty. We assume no liability for consequential damages resulting from a failure of the device or
improper operation.
In the event of a claim under this warranty, please return the device with the proof of purchase to us
postage-paid through the authorized dealer from whom you purchased the device.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Messner UWL 12100 Tec at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Messner UWL 12100 Tec in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish, Finnish as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info