ADD-ON DIGITAL TV (LED,
PREMIUM LED)
Additional power requirements are not needed
for the add-on digital TV. An RG6 coaxial
cable with ‘F Type’ compression fittings will
need to be connected between the video
source and each add-on digital TV unit.
FCC REGULATIONS (USA ONLY)
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning the
equipment o and on, the user is encouraged to try
to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
• Connect the equipment into an outlet on a
circuit dierent from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV
technician for help.
FCC RF Radiation Exposure Statement:
1. This Transmitter must not be co-located or
operating in conjunction with any other antenna
or transmitter.
2. This equipment complies with FCC RF radiation
exposure limits set forth for an uncontrolled
environment. This equipment should be installed
and operated with a minimum distance of 20
centimeters between the radiator and your body.
GROUNDING INSTRUCTIONS
DANGER!
The unit must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current
to reduce the risk of electric shock. The unit is equipped with a
cord having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that
is properly installed and grounded in accordance with all local
codes and ordinances. Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check
with a qualified electrician or serviceman if you are in doubt as
to whether the product is properly grounded. Do not modify
the plug provided with the product. If it will not fit the outlet,
have a proper outlet installed by a qualified electrician.
ADDITIONAL ELECTRICAL INFO
In addition to the dedicated circuit
requirement, the proper gauge wire must
be used from the circuit breaker box, to
each outlet that will have the maximum
number of units running o of it. If the
distance from the circuit breaker box
to each outlet, is 100 ft (30.5 m) or less,
then 12 gauge wire should be used.
For distances greater than 100 ft (30.5
m) from the circuit breaker box to the
outlet, a 10 gauge wire should be used.
ENERGY SAVING / LOW-
POWER MODE
All units are configured with the ability to
enter into an energy saving / low-power
mode when the unit has not been in use
for a specified period of time. Additional
time may be required to fully reactivate
this unit once it has entered the low-power
mode. This energy saving feature may
be enabled or disabled from within the
‘Manager Mode’ or ‘Engineering Mode.
DEDICATED CIRCUIT AND ELECTRICAL INFO
A “Dedicated Circuit” means that each outlet you plug into
should not have anything else running on that same circuit.
The easiest way to verify this is to locate the main circuit
breaker box, and turn o the breaker(s) one at a time. Once
a breaker has been turned o, the only thing that should
not have power to it are the units in question. No lamps,
vending machines, fans, sound systems, or any other
item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit
must have an individual neutral/ground connection coming from
it, and terminating at an approved earth ground. You cannot
“jumper” a single neutral/ground from one circuit to the next.
ELECTRICAL REQUIREMENTS
For your safety and to ensure good treadmill performance,
the ground on this circuit must be non-looped (isolated).
Please refer to NEC article 210-21 and 210-23. Your treadmill
is provided with a power cord with a plug listed below
and requires the listed outlet. Any alterations of this
power cord could void all warranties of this product.
For units with an integrated TV (like the TOUCH and TOUCH
XL), the TV power requirements are included in the unit.
An RG6 coaxial cable with ‘F Type’ compression fittings
on each end will need to be connected to the cardio unit
and the video source. For units with an add-on digital TV
(LED only), the machine in which the add-on digital TV is
connected to powers the add-on digital TV. Additional power
requirements are not needed for the add-on digital TV.
110 V UNITS
110 V units require the use of a 100-125 V, 60 Hz and a
20 A “Dedicated Circuit”, with a non-looped (isolated)
neutral/ground for power. This outlet should be a NEMA
5-20R and have the same configuration as the plug.
No adapter should be used with this product.
220 V UNITS
220 V units require the use of a 216-250 V, 50 Hz and a
20 A “Dedicated Circuit”, with a non-looped (isolated)
neutral/ground for power. This outlet should be a NEMA
6-20R and have the same configuration as the plug.
No adapter should be used with this product.
POWER REQUIREMENTS
North American and
European power
cord plugs shown.
Depending on your
country, the plug
type may vary.
110 NEMA 5-20P
PLUG (N.A.)
220 NEMA 6-20P
PLUG (N.A.)
EURO PLUG
(EUROPE)
ENGLISH
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Matrix Performance Plus Treadmill at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Matrix Performance Plus Treadmill in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 21,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Matrix Performance Plus Treadmill

Matrix Performance Plus Treadmill User Manual - English - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info