785628
19
Zoom out
Zoom in
Previous page
1/20
Next page
SPECIFICATIONS MAGIC
Model MAGIC 24/12-20A MAGIC 24/24-20A MAGIC 12/12-20A MAGIC 12/24-10A
Part no. 81300100 81300200 81300400 81300300
Nominal input voltage 24V 24V 12V 12V
Input range, full output specifications 19-32V DC 19-32V DC 11-16V DC 11-16V DC
Input range, three step charger mode 24-32V DC 24-32V DC 12-16V DC 12-16V DC
Input range, no defects 0-35V DC 0-35V DC 0-17.5V DC 0-17.5V DC
Low voltage set point to trigger alarm * 20.0V DC 20.0V DC 10.0V DC 10.0V DC
Delay lower input set point * 30 sec. 30 sec. 30 sec. 30 sec.
Recommended fuse input 15A-T 30A-T 30A-T 30A-T
Wire size < 3m 4mm²/AWG11 6mm²/AWG9 6mm²/AWG9 6mm²/AWG9
Wire size > 3m 6mm²/AWG9 10mm²/AWG7 10mm²/AWG7 10mm²/AWG7
Output
Voltage adjustable * 10-15V DC 20-28.5V DC 10-15V DC 20-28.5V DC
Nominal voltage stabilized voltage * 13.6V DC 27.2V DC 13.6V DC 27.2V DC
Output voltage 3 step charger
Absorption / Float
14.25 / 13.25V DC
28.5 / 26.5V DC
14.25 / 13.25V DC
28.5 / 26.5V DC
Output voltage dimmer 4.0-13.0V DC 8.0-26.0V DC 4.0-13.0V DC 8.0-26.0V DC
Stabilized 2% at extremes of temperature, load and input
Ripple Max 1% peak peak
Maximum power 300W @ U
out
=12.0V 580W @ U
out
=24.0V 300W @ U
out
=12.0V 300W @ U
out
=24.0V
Rated power 300W @ U
out
=12.0V 580W @ U
out
=24.0V 300W @ U
out
=12.0V 300W @ U
out
=24.0V
Current max. (derating >40°C, 5%/°C) 20A 20A 20A 10A
Maximum 3 step charge current (bulk) 16A 16A 16A 8A
Wire size < 2m 6mm²/AWG9 6mm²/AWG9 6mm²/AWG9 4mm²/AWG11
General
Ambient operating temperature Guaranteed operation: 0°C to 60°C (derating above +40°C, 5% per °C); in practice: -20°C to 60°C/
guaranteed operation: 32 °F to 140 °F (derating above 104 °F, 3% per °F), in practice -4°F to 140 °F
Storage temperature -25°C to 85°C/ -13 °F to 185 °F
Operating humidity 95% max., non-condensing
Galvanic isolation Yes
Current limited Yes, I-max
Three stage battery charge option Yes (DIP switch setting).
Efficiency 90% (at nominal input voltage, full load) typical; 92% peak
No load consumption Typical <115mA
Protections
Over current Limited by current sensing circuit
Over heat Limited power by temperature sense circuit
Options
3 Step battery Charger Yes, all models, by means of DIP switch settings
Dimmer function Yes, by external momentary switch via fast-on connection. To be activated by DIP-switch setting
Alarm contact Yes (fast-on connector)
Communication Quasi RS232, modular RJ12 connection, to alter set points and to change characteristics. Optional:
MasterBus serial interface (art. no. 77030450) to control & configure from MasterBus network.
Parallel connectability In mode Stabilized Voltage, up to 6 devices in parallel
Mechanical
Connections input/output Screw terminals, maximum wire size 16mm² / AWG 5
Dimensions (HxWxD) 227 x 154 x 81 mm [8.9 x 6.1 x 3.2 inch]
Mounting holes Diameter 5mm
Weight 1.8 kg / 3.9 lbs
Cabinet Anodized aluminium, strapton ABS blend, blue RAL 5021
Directives and standards: - EMC directive 2004/108/EC
- Transient voltage protection: meets ISO 7637-2
- Electrostatic voltage protection: meets ISO10605, 14892, 8kV contact, 15kV discharge
- RoHS directive 2011/65/EC
Setpoints software Default setting
Low input voltage switch off level 10.0V / 20.0V; three step charger mode:12.0VDC / 24.0VDC.
Low input voltage switch off delay 30 seconds
Low input voltage switch on level 11.0V / 22.0V; three step charger mode: 13.0VDC / 26.0VDC.
High input voltage switch off level 16.0V / 32.0V
High input voltage switch on level 15.0V / 30.0V
Output voltage 13.6V / 27.2V
* Adjustable by means of MasterAdjust software, see www. mastervolt.com
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Magic 12 24-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Magic 12 24-10 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1.48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info