Hood Description
1) Motor speed button
2) Light button
3) Grease filters
4) Work-lights
Exhausting version
The air is vented outdoors by a duct which
must be connected to the coupling ring S
(See figure 3 “Installation”).
Choosing the exhausting pipe
The coupling ring S has a diameter of
120mm.
We suggest to use Ø 120 mm exhausting
pipe.
Installation
When installed, the hood must be not less
than 65 cm. above electric burners or 75 cm.
above gas or mixed-fuel burners.
Warning!
The hood cannot be connected to flues
of other appliances that run on energy
sources other than electricity.
— When the hood is used at the same time
of other appliances that run on energy
sources other than electricity, provision
must be made for an adequate supply of
air.
No food must be cooked flambé
underneath the hood.
The use of an unprotected flame is
dangerous for the filters and could cause
fires.
Therefore, never use an open flame
under the hood. When frying foods, never
leave the pan alone because the cooking
oil could flare up.
— Please, keep to the provisions of official
directives regarding the question of fume
discharge.
— The manufacturers refuse to accept any
responsibility for damage to the hood or
its catching on fire because of failure to
observe the above instructions.
Suggestions for the installation and
use of the hood
— The horizontal sections of the pipe must
be slanted slightly upwards (about 10%)
to ensure an easy flow of the air outwards.
The best performance of the unit is
obtained in the external exhaust model
(suction), therefore in the limits of the
possibilities it is advised to use the
external exhaust (suction) type.
The best performances are obtained
with short pipes (max. 4 m) and with few
curves.
Electric connection
Before completing any connection, make
sure the house voltage corresponds with
the voltage indicated on the label affixed
inside the hood.
The hood is supplied with a standard plug;
connect it to a correspondingly standard
socket.
In the case is intended to connect the
appliance permanently to the mains after
having removed the plug supplied, must be
fitted a two-pole switch conforming to
regulations with an opening distance
between contacts of not less than 3mm.
The manufacturers are not liable for any
problems caused by the user’s failure to
observe the above instructions.
Mounting the hood - Fig. 3
a. Put the template onto the wall (1) and drill
two Ø12mm holes (2).
b. Fit two hooks (3) on the drilled holes.
c. Remove the metal filters (4), hang the
hood on the hooks and adjust the position
of the hood using the two screws on the
bottom of the hooks (5).
d. and from the inside of the hood mark two
point (6). Remove the hood and drill two
Ø8mm holes on the marked points.
Fit two Ø8mm wall dowels (7), Hang
again the hood and fix the hood definitively
with two screws 5X45 (8) from the inside
of thehood.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marynen CMA 60R at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marynen CMA 60R in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info