Faults with error message display
Error number 10
Gate running sluggish or gate blocked.
Re-establish gate movement.
Maximum drive force set too low.
Have the maximum drive force checked by
qualiedspecialistpersonnelusinganappropriate
force tester.
“Level2,Menu1-RequireddriveforceOPEN”
“Level2,Menu2-RequireddriveforceCLOSE”
Error number 11
Run-time limiting.
Have the drive system checked.
Error number 15
Photocell interrupted or defective.
Remove obstacle or have photocell checked.
Photocell programmed but not connected.
Deactivate or connect photocell.
Error number 16
Current sensor for automatic cut-out defective.
Have motor unit checked.
Error number 26
Undervoltage. Drive system overloaded when drive
force set to stage 16 (maximum).
Have external voltage supply checked.
Error number 28
Gate running sluggish, irregular or gate blocked.
Check gate running and re-establish gate
movement.
Automatic cut-out setting is too sensitive.
Have automatic cut-out checked by specialist
dealer.
“Level2,Menu3-Automaticcut-outOPEN”
“Level2,Menu4-Automaticcut-outCLOSE”
Error number 30
MS-Bus error.
Perform reset of the MS Bus modules:
“Level1,Menu8-RESET”
Have connected BUS modules checked.
Faults with error message display
Error number 33
Overtemperature due to overheating.
Leave the drive system to cool down.
Error number 35
Electronics defective.
Have the drive system checked.
Error number 36
This error number can also be triggered by a connected
expansion module.
Function of stop button programmed, but no stop
button connected.
Connect stop button.
“3.4Connection”
If no stop button is available,
“RESETsafetyelements”or
“RESETBUSmodules”.
“Level1,Menu8-RESET”
Error number 38
Anti-opening mechanism has triggered.
Check gate for signs of a break-in.
Error number 44
8K2 hold circuit of gate leaf has triggered.
Check personnel door to make sure it is correctly
closed.
Error number 48
Gate running sluggish, irregular or gate blocked.
Check gate running and re-establish gate
movement.
Setting of gate positions CLOSED incorrect.
Check gate positions OPEN and CLOSED and reset
if necessary.
Check gate.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Comfort 360 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Comfort 360 in the language / languages: English as an attachment in your email.

The manual is 5,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Marantec Comfort 360

Marantec Comfort 360 User Manual - German - 36 pages

Marantec Comfort 360 User Manual - Dutch - 26 pages

Marantec Comfort 360 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info