691530
3
Zoom out
Zoom in
Previous page
1/9
Next page
3
ENGLISH (Original instructions)
Explanation of general view
SPECIFICATIONS
Due to our continuing program of research and development, the specifications herein are subject to change without
notice.
Specifications may differ from country to country.
Weight according to EPTA-Procedure 01/2003
Intended use
ENE018-1
The tool is intended for blowing dust.
Power supply
ENF002-2
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and can
only be operated on single-phase AC supply. They are
double-insulated and can, therefore, also be used from
sockets without earth wire.
General Power Tool Safety
Warnings
GEA010-1
WARNING Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and
instructions for future reference.
BLOWER SAFETY WARNINGS
GEB073-1
1. Always use protective goggles, a cap and mask
when using the blower.
2. Never point the nozzle at anyone in the vicinity
when using the blower.
3. Warning - Electric shock could occur if used on
wet surfaces. Do not expose to rain. Store
indoors.
4. Never block suction inlet and/or blower outlet.
Increased motor revolution may cause dangerous
fan breakage.
5. The blower is not intended for use by young
children or infirm persons without supervision.
6. Young children should be supervised to ensure
that they do not play with the blower.
SAVE THESE INSTRUCTIONS.
WARNING:
DO NOT let comfort or familiarity with product (gained
from repeated use) replace strict adherence to safety
rules for the subject product. MISUSE or failure to
follow the safety rules stated in this instruction
manual may cause serious personal injury.
FUNCTIONAL DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and
unplugged before adjusting or checking function on the
tool.
Switch action
CAUTION:
Before plugging in the tool, always check to see that
the switch trigger actuates properly and returns to the
“OFF” position when released. (Fig. 1)
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
For continuous operation, pull the switch trigger and then
push in the lock button, and then release the switch
trigger.
To stop the tool from the locked position, pull the switch
trigger fully, then release it.
Air volume adjusting dial (Fig. 2)
Air speed and volume can be adjusted without positive
stops by turning the air volume adjusting dial.
To obtain high speed and increase volume, turn the air
volume adjusting dial to the A direction shown in the figure
(for the bigger number). Turn the air volume adjusting dial
to the B direction (for the smaller number) to obtain low
speed and to decrease the air volume.
1. Switch trigger
2. Lock button
3. Air volume adjusting dial
4. Nozzle
5. Pin
6. Blower outlet
7. Notch
8. Sash nozzle
Model M4000
Capacities Max. air volume 1.2 - 2.9 m
3
/min.
No load speed (min
-1
) 8,500 - 16,000
Overall length 427 mm
Net weight 1.5 kg
Safety class /II
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Makita M4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Makita M4000 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info