599356
23
Zoom out
Zoom in
Previous page
1/24
Next page
Figure
20
DISCRIMINATION ADJUSTED PROPERLY
Figure
21
To
adjust
the shallow
(top)
alarm,
press
the SHALLOW SET
key,
then
press
the
up
arrow
key
to move the
top
of the alarm window
up,
or the
down arrow
key
to move the
top
of the zone
deeper.
The
longer you
hold
the
arrow
key,
the
faster the end
of the
zone
alarm bar will
travel.
The
bottom of the zone can be set in the same manner
using
the DEEP SET
key.
Press the
DEEP
SET
key,
then
press
either the
up
arrow
key
to make
the bottom
part
of the window move
shallower,
or
press
the down arrow
key
to move the bottom of the window
deeper.
After
the
keys
are
released,
the bar will remain on the screen for six
seconds,
and then
disappear.
As
long
as the "ZONE ALARM"
signal
is
displayed,
the alarm is
engaged.
If
you
wish to view the zone alarm
bar,
simply press
either the
SHALLOW SET or DEEP SET
keys
and the bar will be
displayed
for six
seconds. It can be turned on
permanently by pressing 2nd,
downarrow
(DISPLAY).
To turn it back
off, simply press 2nd,
downarrow
(DISPLAY)
again.
If the zone alarm is set off
by
a fish or the
bottom,
the alarm will sound
and the words ZONE ALARM will flash
at
the bottom
of the
display.
If the
range
is
changed,
the zone alarm
may
need to be
changed too,
since it does not track
range settings.
CLEARING THE ZONE ALARM
To turn the Zone Alarm
off, press CLEAR,
SHALLOW SET or DEEP
SET or
press CLEAR, uparrow
or downarrow.
All of the Zone Alarm
set-
tings
will remain in
memory.
Pressing
either
SHALLOW
or DEEP SET
keys
will turn the Zone Alarm back on with the
previous settings.
key.
Discrimination
may
be turned off
by pressing
0,
DISC or
CLEAR,
DISC.
To view the Discrimination
setting
without
changing
it,
press
the DISC
fl112
TEMP °r/°C
I
TEM PERATU RE
To
display
the surface water
temperature, press
2nd,
1
(TEMP).
The
temperature
will be
displayed immediately
above the
digital
bottom
depth
in
degrees
Fahrenheit. See
Figure
22. To turn the
temperature display
off,
press
2nd,
1
(TEMP) again.
The
temperature display
can be
changed
from
degrees
Fahrenheit to
degrees
Celsius.
To
change, press
2nd,
2
(F/C).
A menu
(see figure 23)
will
appear showing
the current
temperature
mode. To
change
modes,
press
1
for
degrees
Fahrenheit,
2 for
degrees
Celcius,
or CLEAR for no
change.
The menu will
disappear
after six seconds if no
keys
are
pressed, leaving
the
temperature display
in the current mode.
NOTE KEY
[.r
PRESET
The
note
key
turns the audible tone off and on. When
the X-50 is first
turned
on,
the audible tone
is on
and a "note" at
the
bottom of
the screen is
displayed.
To turn the audible tone
off, press
the note
key
on the
keyboard
once. To turn it back
on, press
the
note
key
:
again.
, U!i[C1Iv—1.]Fl;.
I
DIGITAL SHALLOW DEEP
10TH ALARM ALARM
DEPTH ALARM
The
Depth
Alarm is
actually
two alarms. The shallow alarm
gives
a
warning
when
you're
in water shallower than the alarm set
point.
The
deep
alarm
gives
a
warning
in water
deeper
than the alarm set
point.
The bottom
signal
is the
only
echo that will
trigger
either the shallow alarm or the
deep
alarm.
DISCRIMINATION OFF
24 21
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lowrance X-50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lowrance X-50 in the language / languages: English as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info