8
WARNING:
Special cable must be used to connect indoor unit and outdoor unit. It should be ensured
that the terminals are not influenced by external force. Poor connection may cause fire.
The electric box cover must be mounted and secured in position, otherwise fire or electrical
shock may occur because of dust or moisture.
The connecting cables must be clipped together.
Please take the electric circuit diagram attached to the indoor/outdoor units as major
reference while installing.
The power wire and signal wire between the indoor/outdoor units must be connected
one by one as per corresponding number on the wiring terminal board.
All the models shall be connected with the mains which has system impedance limitations.
While installing the unit, please see the following table for impedance information or consult
with the supply authority.(The following information and specifications are subject to change
without prior notice due to continuing research.)
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the connecting tube.
SERIES MODEL
IMPEDANCE
0.204Ω
0.162Ω
0.148Ω
0.323Ω
6500W (22000BTU/h)
5100W (18000BTU/h)
2500W (9000BTU/h)
3500W (12000BTU/h)
R407C
series
6800W (24000BTU/h)
5100W (18000BTU/h)
3200W (11000BTU/h)
3500W (12000BTU/h)
R22
series
0.116Ω
0.160Ω
0.312Ω
0.312Ω
2500W (9000BTU/h)
0.467Ω
0.187Ω
0.124Ω
0.138Ω
0.268Ω
Dual Split Model(25+25)
Dual Split Model(25+35)
0.302Ω
2000W (7000BTU/h)
0.121Ω
3200W (11000BTU/h)
0.121Ω
3300W (11500BTU/h)
R410A
series
6800W (24000BTU/h)
5100W (18000BTU/h)
Notice:
If the interconnection cord for power supply has to be replaced, please see the
following table for reference.
If you find the color of connecting cable not comply with the top diagram, please take
real objects as major reference. But the terminal of the same sign must be joint with
the connecting cable of the same color.
If the signal wire has to be bought separately, choose electric wire above 0.75mm.
The plug housing 2 is connected to the matched receptacle housing of the outdoor unit.
The plug housing 1 is connected to the matched receptacle housing of the indoor unit.
If not include the connect diagram you need, please see the wiring diagram.
MODEL
SPECS (Interconnection cord)
2700W(10000BTU/h)
1.0mm
3200W(11000BTU/h)
-4000W(15000BTU/h)
4500W(16000BTU/h)
-8000W(28000BTU/h)
1.5mm
2
2
2.5mm
2
8500W(29000BTU/h)
-9500W(32000BTU/h)
4.0mm
2
6.0mm
2
10000W(34000BTU/h)
-11000W(38000BTU/h)
If not include the connect diagram you need, please see the wiring diagram.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lloyd LS9A3P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lloyd LS9A3P in the language / languages: English as an attachment in your email.

The manual is 0,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Lloyd LS9A3P

Lloyd LS9A3P User Manual - English - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info