15
* measuring distance up to 10 m with strongly reflective target
surface and at room temperature. The measurement deviation
may increase by +/-0.2 mm/m for greater distances and under
unfavourable measuring conditions such as strong sunlight or
weakly reflective target surfaces.
Technical Data (Subject to technical changes without notice)
Inside measurement range 0,5 m - 25 m
Precision (typical) ± 3 mm / 10 m*
Laser class 2 < 1mW
Laser wavelength 650 nm
Power supply 2 x AAA 1.5 Volt batteries
Dimensions 110 x 43 x 28 mm
Weight (incl. batteries) 110 g
Automatic switch-off
30 sec LCD lighting /
45 sec laser / 3 min device
Operating temperature 0°C – 40°C
Storage temperature -20°C – 70°C
Article number 080.944A
Error codes:
301:
302:
303:
304:
305:
306:
307:
308:
Target is outside measuring range.
Target is too dark or too much ambient light. Use
a reflecting material as target for the measurement.
Measured value cannot be shown by LC display.
Set measured values to zero with button (4.).
Pythagoras parameter error
Replace the battery.
Temperature is too low: < 0 °C
Temperature is too high: > 40 °C
Too much ambient light.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
GB
Manual_LRM-X2_Rev.0911_Part_1.indd 15 23.09.11 10:57
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner LaserRange-Master X2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner LaserRange-Master X2 in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Laserliner LaserRange-Master X2

Laserliner LaserRange-Master X2 User Manual - English, German, Dutch, Danish, French, Italian, Polish, Swedish, Spanish, Finnish - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info