706757
4
Zoom out
Zoom in
Previous page
1/20
Next page
English 4 / 20
EN FR NL CS SK SL RO BG LT
ENGLISH
INTRODUCTION
Thank you for choosing the Mahé by LANA-
FORM The Mahé essential oil diuser com-
bines technology, well-being and design.
Virtually silent, it not only spreads a cool
fragrant mist, but also diuses a gentle white
light around your home.
The photographs and other
images of the product in this manual
and on the packaging are as accurate
as possible, but do not claim to be a
perfect reproduction of the product.
Description of the device
1
1 Reservoir
2 Transducer
3 Water sensor and minimum water level
4 Transducer stand
5 Stand cover
6 Suction pads
7 Power cable and transformer
8 Maximum water level
Features
White alternating LED light
900 ml capacity
12 hours of continuous diusion
Easy-to-ll water reservoir
With the water sensor, the device stops
automatically when there is no more water
left in the reservoir
PRECAUTIONARY MEASURES
Please read all the
instructions before using your
humidier, especially this
basic safety information.
Always place the diuser on a hard, at,
horizontal surface. Keep it away from
walls and heat sources such as stoves,
radiators, etc.
Check that your mains voltage is the same
as that of your device.
Do not connect or disconnect the mains
plug with wet hands.
If the power cable is damaged, it must be
replaced by a similar cable available from
the supplier or the supplier’s after-sales
department.
Do not leave the device in the sun for long
periods of time.
Do not dismantle the device entirely.
Do not switch on the diuser when there
is no water in the reservoir.
Do not touch the transducer when the
device is on.
Do not use essential oils that are not rec-
ommended for diusion.
Use only the mains adaptor supplied with
this device. The adaptor supplied should
only be used with the device and not for
other purposes or with other devices.
Do not use perfume or synthetic essences
as these could damage the device.
Make sure that the cable does not go
directly above the transducer.
Do not pull on the water sensor or you
may damage the device.
Unplug the device before cleaning it.
Do not wash the entire unit with water
and do not immerse it in water. Consult
the cleaning instructions in this manual.
Never scrape the transducer with a hard
tool and consult the cleaning instructions
in this manual.
The Mahé should preferably be used for 30
minutes at a time, but can be used several
times a day if you wish.
This device is not intended for use by
people, including children, with reduced
physical, sensory or mental capabilities,
or people with a lack of experience or
knowledge, unless someone responsible
for their safety can supervise or instruct
them beforehand on how to use the de-
vice. Children should be supervised to
make sure they do not play with the device.
INSTRUCTIONS FOR USE
AL
Place the Mahé in the room half an hour
before turning it on to allow it to adjust
to room temperature.
Make sure that the diuser is clean.
Look at the diagrams in these instructions
for setting up the diuser. Make sure they
are positioned exactly as shown on the
diagram. Check that the suction pads
[
6]
are xed properly under the transducer
stand
[
4]
. Position the transducer
[
2]
on its stand, checking that is it is held in
the correct position. Fix the base to the
bottom of the reservoir using the suction
pads. Check that the cover
[
5]
is xed
properly to the transducer stand. Then
remove the cable of the water sensor and
LED light generator through the hole pro-
vided for this purpose. Please block this
hole using the rubber bung on the cable.
Fill the reservoir with clean water up to
the level indicated between the minimum
level at water sensor level [
3] and the
maximum level on the transducer stand
[
8]
. The temperature of the water should
not exceed 40°C.
Pour a few drops of essential oil into the
reservoir.
With dry hands, connect the power supply
plug. The device switches on automatical-
ly. The mist and light it diuses thus create
an atmosphere that encourages relaxation.
Additional information
about the use of essential oils
Before using essential oils, please check
the harmful eects that use of these prod-
ucts may have on your health.
Always choose quality essential oils that
are pure, 100% natural and intended for dif-
fusion. Use them in moderation and with
care. Follow the instructions and warnings
stated on the packaging of the essential
oils, making sure in particular that:
Pregnant women, people with epilepsy,
asthmatics and people who suer from
allergies, those with heart problems or se-
rious illnesses should not use essential oils.
Essential oils should be used only for peri-
ods not exceeding 10 minutes in the room
of a baby (under 3 years old) and only
when the baby is not actually in the room.
Make sure that children and minors do
not play with or use the device.
Just a few drops (3 to 4 drops at most) of
essential oils are sucient to ensure that
the device works properly and the scent
is diused. Excessive use of essential oils
could damage the device.
Make sure you pour water into the res-
ervoir rst before adding the drops of
essential oils.
Lanaform cannot be held liable in the
event of accidental damage resulting from
any use contrary to the instructions given
in these instructions for use.
Even though there is a
safety device that stops the
transducer running, do not
leave the device connected
when you are not using it.
MAINTENANCE AND STORAGE
If the water contains too much calcium and
magnesium, it may deposit a white powder
in the device. If this foam is deposited on
the transducer (metallic ring emitting ultra-
sounds), this will prevent the device from
working properly.
Precautions
1 Use water that has been boiled
and cooled each time it is used;
2 Clean the reservoir every 2 days and
clean the transducer every week;
3 Change the water in the res-
ervoir every 2 days;
4 Clean the device and make sure
that all its parts are complete-
ly dry when it is not in use.
E-IM-Mahé-001-v1.0.indd 4 13/08/2019 16:56:16
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lanaform Mahe - LA120320 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lanaform Mahe - LA120320 in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 2,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info