28 Service Manual
For internal use only
10.2 Internal faults
Component Possible cause Possible repair measures
High voltage diode Diode in short circuit.
Diode in open circuit.
If the high voltage diode is in short
circuit, the fuse may not blow but the
transformer secondary winding will
overheat. Replace the high voltage
diode.
If the circuit has been interrupted the
transformer will make peculiar
noises. Replace the diode.
Magnetron Magnetron filament in open circuit.
Magnetron in short circuit.
Check the continuity of the filament
with the cables disconnected. If there
isn’t continuity, the filament is broken.
Replace the magnetron.
Check the continuity between the
magnetron terminals and the body. If
there is continuity the magnetron is
defective. Replace the magnetron.
Digital / electro-mechanical programmer Digital programmer.
Electro-mechanical programmer.
Microwave and/or grill function
control failure. -> Replace the digital
programmer.
Time and control error function fault
-> replace the electro-mechanical
programmer.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kuppersbusch EMWG 1050 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kuppersbusch EMWG 1050 in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kuppersbusch EMWG 1050

Kuppersbusch EMWG 1050 User Manual - German - 33 pages

Kuppersbusch EMWG 1050 User Manual - Dutch - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info