694605
16
Zoom out
Zoom in
Previous page
1/100
Next page
16
3. Description of the appliance
Drawing 1. General construction diagram of the replace insert Zuzia with a vertical air heater with
water jacket.
Drawing 2. General construction diagram of the replace insert with water jacket.
The main component of the replace insert with water jacket is its steel water jacket (16) where the
combustion chamber (1) is located. The front wall of the combustion chamber is the cast iron door
(2) equipped with a homogenous heat-resistant glass ceramics (3) and a locking bolt (4). The door is
settled in a cast iron frame (5) screwed to the water body. From the bottom the combustion chamber
(1) is limited by a cast iron base (6) screwed to the water body where an ashpan chamber is located.
Above the base there is a cast iron grate (10) where fuel is burnt. The grate should be placed with its
nning faced upwards. An ashpan cast iron guard (11) protects against spilling of incandescent fuel
from the combustion chamber after opening the door (2) Ashpan waste: ash and residues of unburnt
fuel are accumulated in a sliding ashpan drawer (7) located under the grate. In the front part of the
ashpan drawer a window (8) equipped with a controllable throttle with a handle (9) for controlling
the amount of primary air needed to burn fuel. The secondary air needed to reheat gases arising from
fuel burning and protecting against the blackening of the heat-resistant glass (3) is supplied by the
slot in the upper part of the glass. Over the combustion chamber there are smoke tubes (17) whose
diameter depends on the insert power, welded to lateral inner walls of the water body constituting
natural convection ducts for ue gases ow and simultaneously intensifying the exchange of heat.
During the operation after the re-up of fuel ue gases ow along the combustion chamber walls
between the smoke tubes to the vent connector (12) then through the ue to the chimney. In the
vent connector there is a starting rotationally controlled damper (13). A knob (15) is used to adjust
the angle of the damper opening by a special mechanism (14).
The inlet of circulating water from the system to the replace insert with water jacket takes place by
a lower stub pipes (18). The discharge of heated water from the replace insert to the central heating
system (with water set) takes place also by upper stub pipe (19).
The rest of stub pipes (20) are used to x the temperature sensor (MSK), (21) coil pipe, (22) thermal
valve sensor.
3.1. Selection of the thermal power of central heating system or domestic hot water system
The primary criterion for the selection of the system thermal power is the maximum transient power
of the replace insert water jacket. A central heating system or domestic hot water system may carry
the rated (average) power of the water jacket declared by its Producer when its takeo power is equal
or close to the maximum transient power of the water jacket. Relevant technical data are included
in table 1.
4. Assembly and installation of the replace insert with water jacket
The replace insert should be installed by a person having required qualications. Before starting to
connect the replace insert with water jacket to the central heating and smoke removal system, read
carefully this manual and check the completeness of the appliance equipment.
Before placing the replace insert with water jacket, prepare a foundation minimum 30cm above
the oor (not relevant in all countries, depending on the material and construction of the oor) of
the room where the replace insert with water jacket is to be operated. The appliance placed on the
oor should be carefully leveled and then it should be connected to the central heating and smoke
removal duct, the ttings of the replace insert with water jacket should be assembled.
4.1. The principles of safe installation of the replace insert with water jacke
Health and safety rules, principles of correct and safe assembly of the replace in- sert with water
jacket, ventilation and connection to the ue gas removal system are dened in the Regulation of the
Minister of Infrastructure dated 12 April 2002 DZ.U. no. 75 dated 15 June 2002 in chapter 6 § 265 p.1;
§ 266 p.1; § 267 p.1.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kratki MILA 24*** at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kratki MILA 24*** in the language / languages: English, German, French, Polish as an attachment in your email.

The manual is 4,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info