INSTRUCTION MANUAL
Mini Alarm - MODEL SEC-APD10
Mini Alarm, Motion Detector with Auto Dialler
Controls
1. Motion Sensor 5. Keypad
2. Speaker 6. Telephone Plug Socket
3. Mic 7. Battery Compartment
4. Low battery warning
Indicator light
Battery installation
1. The battery compartment is accessed from the rear of the alarm
unit by removing the screw from the base of the unit and lifting the
rear cover-fixing bracket B.
2. Insert four AAA size batteries (not included) following the polarity
as shown C. When the last battery is inserted the alarm will beep
very loudly to indicate that the batteries are installed properly (see
programming the alarm).
3. Replace the back cover and fix with screw.
The Low battery warning indicator light will illuminate when the
batteries need replacing.
Installation
1 Place the alarm in the desired location.
2 Remove the rear cover and fix it to the wall using the screws
supplied.
3 The alarm body can then be snapped into place onto the rear cover
and secured using the screw at the base of the unit.
Please note: This alarm can also be used in a free standing position.
Programming the alarm
Immediately after inserting the batteries, the 4-digit security code must
be set, simply press the desired 4 digits code onto the keypad. Do not
press ”0”as the first digit of your personal code as “0” is the digit to arm
the alarm.
Note: The alarm unit must be re-programmed with your security code
each time the batteries are removed or replaced.
If you are required to change the personal code for any reason you
must remove the batteries. Insert the batteries following section C,
when the last battery is inserted you will hear a loud beep, now enter
your new four digit security code. You do not need to remove the
batteries to store any new telephone numbers or record a new voice
message.
Storing telephone Number
Press and store 1st group of telephone No. and press to
confirm storing. Press
for 2nd group of telephone No. and so
on. Maximum 3 sets of telephone number with max 16 digits can be
stored. Note: Only use friends and families telephone numbers. Do
not use emergency service numbers.
Can be used with a PABX phone system.
Recording a message
Press the low battery indicator light will illuminate, you
now have 6 seconds to record your personal message. Once the light
goes off your recording time is over.
Suggested message: This is an alarm call from?
The alarm unit has a permanent memory for stored telephone
Numbers and the recorded voice message. To change the
telephone number or recorded message, repeat above.
Using the SEC-APD10 as a silent alarm.
You have the option to disable the siren by pressing
. To retrieve the siren press
Connection to the telephone unit
1 Remove the screw at the base of the alarm unit.
2 Remove the back plate and connect the telephone socket
into the alarm unit 6. The other end of the cable is connected
into the telecom wall socket.
Operation
Leaving the protected area
Press keypad number
you will hear a confirmation tone
this will indicate that the alarm is armed. You now have 30
seconds to vacate the area. After this time, if motion is
detected the alarm will start to dial the stored telephone
numbers and the alarm siren will sound 20 seconds after the
first telephone number is dialled.
Entering the protected area
Type in your 4-digit security code within 10 seconds and this
will disarm the alarm.
When the unit is activated, it will dial the first telephone number
stored. If the first telephone number is not answered within 45
seconds the second stored number will be dialled and so on.
All three stored telephone numbers will be dialled if the
unit is activated unless the security code is entered to
disarm the alarm.
Detection Area
Care and maintenance
To clean the case, simply use a soft slightly damp cloth with water and
wipe dry immediately.
Caution: Never use chemicals to clean the case, as they may cause
damage to the plastic and cause the alarm not to function.
Trouble shooting
The unit does not sound when the batteries are installed
Ensure that the batteries are connected correctly according to the
diagram in the battery compartment
The alarm does not arm
Ensure that the back plate of the alarm unit is secure to hold the
batteries in place and that the red light comes on when the keypad
buttons are pressed
The red light located in the middle of the alarm 4 is on
This is the low battery warning indicator light. The batteries need
replacing
Battery precautions
When using this product follow these precautions at all times.
· Use only the appropriate size batteries
· Be sure to follow the correct polarity when installing the batteries as
indicated in the battery compartment. Incorrect polarity may cause
damage to the alarm.
· Do not mix different types of battery such as Alkaline and
Carbon-zinc or old batteries with new.
· If the alarm is not used for long periods of time, remove the batteries
to prevent damage or injury from possible battery leakage.
· Do not recharge batteries not intended to be recharged as they can
overheat and rupture. (Always follow the manufacturer's directions.)
6/2005


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Konig Electronic SEC-APD10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Konig Electronic SEC-APD10 in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Konig Electronic SEC-APD10

Konig Electronic SEC-APD10 Quick start guide - English, German, Dutch - 4 pages

Konig Electronic SEC-APD10 User Manual - Dutch - 4 pages

Konig Electronic SEC-APD10 Quick start guide - Danish, French, Italian, Swedish, Spanish, Norwegian, Finnish - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info