APPENDIX
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads transmit power.
PC
POWER CONTROL
P1 47 POWER
CONTROL
PC P1 ;
PC ;
P1PC ;
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets Speech Processor OFF/ON or reads status.
PR
SPEECH PROCESSOR
P1 1 SPEECH
PROCESSOR
OFF/ON
PRP1
PRP1;
PR ;
;
Parameter
Format
Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets Power OFF/ON or reads status.
PS
POWER SWITCH
P1
1
POWER
OFF/ON
PSP1
PSP1;
PS ;
;
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads CW RX pitch.
PT
CW RX PITCH
P1
52
CW RX PITCH
PT
P1
PT
PT ;
;
P1
;
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads RF ATT(attenuator).
RA
RF ATTENUATOR
P1 ATTENUATOR
RA
RA ;
P1RA ;
P1 ;
00: OFF
01: ON
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Lowers/raises RIT frequency.
RD
R
;
RIT DOWN/UP
D/U
Note:
This command also affects the XIT
frequency (same as RIT shift).
The command functions
independently from the RIT/XIT
control.
RU
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets RIT OFF/ON or reads status.
RT
RIT
P1 1 RIT OFF/ON
RTP1
RTP1
;
RT
;
;
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets the RIT frequency shift to 0.
RC
R;
RIT CLEAR
C
Note:
This command also clears the XIT
frequency (same as RIT shift).
The command functions
independently from the RIT/XIT
control.
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Selects a meter function or reads meter values.
RM
READ METER
P1
24
METER SWITCH
R
M
P1
;
RM
;
P1
RM
;
P2
P2
22
METER VALUE
Parameter Format Parameter function
1 234567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads RF gain.
RG
RF GAIN
P1 31
RF GAIN
R
GP1
R
G
P1
R
G
;
;
;
85


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-570D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-570D in the language / languages: English as an attachment in your email.

The manual is 4,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-570D

Kenwood TS-570D User Manual - German - 88 pages

Kenwood TS-570D User Manual - Dutch - 88 pages

Kenwood TS-570D User Manual - French - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info