686297
31
Zoom out
Zoom in
Previous page
1/32
Next page
29
© Kemppi Oy / 1520
DE
10. TECHNISCHE DATEN
FastMig X 350 X 450
Anschlussspannung 3~50/60 Hz 400 V, -15 bis +20 % 400 V, -15 bis +20 %
Anschlussleistung 60 % ED 22,1 kVA
80 % ED 16,0 kVA
100 % ED 15,3 kVA 16,0 kVA
Anschlusskabel HO7RN-F 4G6 (5 m) 4G6 (5 m)
Sicherung Verzögert 35 A 35 A
Ausgangsleistung bei 40°C 60 % ED 450 A
80 % ED 350 A
100 % ED 330 A 350 A
Schweißstrom und Spannungsbereich E-Hand 15 A / 20 V – 350 A /
46 V
15 A / 20 V – 450 A /
46 V
MIG 20 A / 12 V – 350 A /
46 V
20 A / 12 V – 450 A /
46 V
Max. Schweißspannung (E-Hand) 46 V 46 V
Leerlaufspannung E-Hand U
0
= 70 - 98 V
U
av
= 50 V
U
0
= 70 - 98 V
U
av
= 50 V
MIG/MAG/Puls U
0
= 80 – 98 V U
0
= 80 – 98 V
Leerlaueistung 100 W 100 W
Leistungsfaktor bei Höchststrom 0,85 0,88
Wirkungsgrad bei 100 % ED 87 % 87 %
Betriebstemperatur -20 bis +40 ºC -20 bis +40 ºC
Lagertemperatur -40 bis +60 ºC -40 bis +60 ºC
EMV-Klasse A A
Kurzschlussstrom S
sc
des Versorgungsnetzes
mindestens*
5,5 MVA 5,5 MVA
Schutzart IP23S IP23S
Abmessungen L x B x H 590 x 230 x 430 mm 590 x 230 x 430 mm
Gewicht 38 kg 38 kg
Spannungsversorgung für Hilfsgeräte 50 V DC / 100 W 50 V DC / 100 W
Sicherung (Zusatzgerät) Verzögert 6,3 A 6.3 A
Spannungsversorgung für Kühleinheit 24 V DC / 50 VA 24 V DC / 50 VA
Die empfohlene Mindestleistung des Generators beträgt 35 kVA.
*Siehe Abschnitt 2.2.: Verteilnetz
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi FastMig X 450 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi FastMig X 450 in the language / languages: German as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kemppi FastMig X 450

Kemppi FastMig X 450 User Manual - English - 32 pages

Kemppi FastMig X 450 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info