FastMig X 350 X 450
Connection voltage 3~50/60 Hz 400 V, -15…+20 % 400 V, -15…+20 %
Rated power 60 % ED 22.1 kVA
80 % ED 16.0 kVA
100 % ED 15.3 kVA 16.0 kVA
Connection cable HO7RN-F 4G6 (5 m) 4G6 (5 m)
Fuse Delayed 35 A 35 A
Output 40 °C 60 % ED 450 A
80 % ED 350 A
100 % ED 330 A 350 A
Welding current and voltage range MMA 15 A/20 V – 350 A/46 V 15 A/20 V – 450 A/46 V
MIG 20 A/12 V – 350 A/46 V 20 A/12 V – 450 A/46 V
Max. welding voltage MMA 46 V 46 V
Open circuit voltage MMA U
0
= 70 – 98 V
U
av
= 50 V
U
0
= 70 – 98 V
U
av
= 50 V
MIG/MAG/Pulse U
0
= 80 – 98 V U
0
= 80 – 98 V
Open circuit power 100 W 100 W
Power factor at max. current 0.85 0.88
Eciency at 100 % ED 87 % 87 %
Operating temperature range -20…+40 °C -20…+40 °C
Storage temperature range -40…+60 °C -40…+60 °C
EMC class A A
Minimun short circuit power S
sc
of supply network* 5.5 MVA 5.5 MVA
Degree of protection IP23S IP23S
External dimensions L x W x H 590 x 230 x 430 mm 590 x 230 x 430 mm
Weight 38 kg 38 kg
Voltage supply for auxiliary devices 50 V DC / 100 W 50 V DC / 100 W
Fuse (auxiliary device) Delayed 6.3 A 6.3 A
Voltage supply for cooling unit 24V DC / 50 VA 24V DC / 50 VA
The minimum recommended generator output is 35 kVA.
* See section 2.2: Distribution network.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi FastMig X 450 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi FastMig X 450 in the language / languages: English as an attachment in your email.

The manual is 1,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kemppi FastMig X 450

Kemppi FastMig X 450 User Manual - German - 32 pages

Kemppi FastMig X 450 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info