2.5.5 Cables
Kemppi always recommend the use of high quality copper cables with a suitable cross-
sectional area. Cable size should be selected depending on the intended welding application.
50 mm² copper cables may be used for low duty work in basic or synergic 1-MIG. However,
using pulsed MIG/MAG process, longer cables, or higher welding power increase the voltage
loss, and therefore smaller cross sectional interconnection cables and earth return cables will
restrict the welding performance of your machine.
Recommended cross-sectional area of FastMig X 350MV cables: 70 – 95 mm².
The enclosed table shows typical load capacities and voltage loss values of rubber insulated
copper cables for duty cycles 100%, 60% and 30%, when ambient temperature is 25 °C and
the cable temperature is 85 °C.
Cable size 100 % 60 % 30 % Voltage loss / 10 m
50 mm²
285 A 370 A 520 A 0.35 V / 100 A
70 mm²
355 A 460 A 650 A 0.25 V / 100 A
95 mm²
430 A 560 A 790 A 0.18 V / 100 A
Do not overload the cables due to voltage losses and heating.
NOTE! Always check the serviceability of the earth return cable and clamp. Ensure the metal
surface to which the cable is connected is clean from metal oxide or paint. Check the connector to
the power source is fastened correctly.
2.5.6 Interconnection with wire feeder
Kemppi provide a choice of interconnection cable sets for dierent environments. Only
materials that meet the demands of Kemppi's international markets are used in their
construction.
Used correctly, Kemppi cable sets ensure high welding performance and serviceability.
Before use, always ensure the cable set is in good condition and that connectors are correctly
fastened. Loose connections reduce welding performance and may result in damage to
connectors due to heating eects.
For correct connection and conguration of cable sets, please refer to schematic drawings in
section 2.5 of this manual.
NOTE! FastMig X 350MV power sources are designed to be used with WFX wire feed units.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi FastMig X 350MV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi FastMig X 350MV in the language / languages: English as an attachment in your email.

The manual is 1,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info