A7 MIG Welder© Kemppi Oy 2018 1824
OPERATING MANUAL
10. TECHNICAL DATA
A7 MIG Power Source 350, 450
A7 MIG Power source 350 450
Supply voltage 3~ 50/60 Hz 400 V, -15 % … +20 % 400 V, -15 % … +20 %
Mains connection cable H07RN-F 4G6 (5 m) H07RN-F 4G6 (5 m)
Maximum supply current 23 A 32 A
Eective supply current 21 A 25 A
Fuse 25 A delayed 35 A delayed
No-load voltage (peak) U0 = 85 V – 95 V U0 = 85 V – 95 V
Open circuit voltage (average) 85 V 103 V 85 V 103 V
Operating temperature range -20 °C … +40 °C -20 °C … +40 °C
Minimum generator power 35 kVA 35 kVA
External dimensions LxWxH 610 x 240 x 520 mm 610 x 240 x 520 mm
Weight (no mains connection cable) 40.2 kg 40.2 kg
Weight (with mains connection cable) 42.6 kg 42.6 kg
Degree of protection IP23S IP23S
Eciency (100 % duty cycle) 87 % 87 %
Power factor (at max. current) 0.85 0.88
Storage temperature range -40 °C … +60 °C -40 °C … +60 °C
Temperature class (main transformer) 155 (F) 155 (F)
EMC class A A
Minimum short circuit power Ssc of supply network 5.5 MVA 5.5 MVA
Welding range 20 A / 12 V - 350 A / 46 V 20 A / 12 V - 450 A / 46 V
Output (at 60 % duty cycle) 350 A 450 A
Output (at 100 % duty cycle) 330 A 350 A
Power supply for auxiliary devices 50 V DC / 100 W 50 V DC / 100 W
Max. apparent power 22 kVA 22 kVA
Idle power 25 W 25 W
Power supply for cooling unit 24 V DC / 50 VA 24 V DC / 50 VA
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 MIG Power Source 450 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 MIG Power Source 450 in the language / languages: English as an attachment in your email.

The manual is 3,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info