478078
12
Zoom out
Zoom in
Previous page
1/16
Next page
Kelvinator Air Conditioning Troubleshooting 9
Problem Cause
Water leakage of
outdoor unit
•Duringcoolingoperation,water
condensates around the pipes and
connection joints.
•Duringdefrostingoperation,thawed
water flows out.
•Duringheatingoperation,wateronthe
heat exchanger drips out.
Noise from indoor
unit.
•Thenoiseemittedwhenthefanor
compressor relay is switched on or off.
•Whenthedefrostingoperation
is started or stopped, there is a
sound of refrigerant flowing in the
reverse direction.
Indoor unit can not
blow air
•InHEATmode,whenthetemperature
of indoor heat exchanger is very low,
air flow is stopped in order to prevent
cold air. (within 2 minutes)
•InHEATmode,whentheoutdoor
temperature is low or humidity is high,
frost will be formed on the outdoor
heat exchanger. The unit will defrost
automatically and indoor unit will stop
blowing air for 3-12 minutes.
•Duringdefrostingoperation,wateror
vapour may be emitted.
blowing air for 3-12 minutes in order
to avoid condensing water being
vaporised again.
Moisture on air
outlet
•Iftheunitoperatesathighhumidityfora
long time, moisture will be generated on
the air outlet grill and then drip off.
E3: Low pressure
warning
Your air conditioner has lost refrigerant.
Contact your installer to check for
potential leaks.
The pressure in the refrigeration system is low and could result
in the unit breaking down. Ask a certified installer to control it.
If any one of the following situations occurs, immediately stop
all operations, disconnect the power supply, and contact the
authorised personnel.
• Thereisaharshsoundduringoperation.
• Strongodoursareemittedduringoperation.
• Waterisleakingfromtheunit.
• Thecircuitbreakeroftentrips.
• Waterorotherliquidissplashedintotheunit.
• Powercordandpowerplugisoverheating.
The air conditioner is not user serviceable. Incorrect repair
may cause electric shock or fire, so please contact an
authorised service center for professional repair.
The following checks prior to contact may save you time
and money.
Problem Cause
The unit does not
operate
The unit does not operate if it is
turned on immediately after it is
turned off. This is to protect the unit.
You should wait about 3 minutes.
Odours are emitted
•Someodoursmaybeemitted
from the indoor unit. This is the
result of room smells (such as
furniture,tobacco,etc.) which have
been taken into the air conditioner.
•Consultauthorisedservicecentrefor
cleaning if the odours persist.
"Water flowing" noise
The swishing noise like water flowing is
the refrigerant flowing inside the unit.
Mist is emitted in
COOL mode
During cooling operation, a thin mist
may be seen emitted from the indoor
unit due to high room temperature
and humidity.
After a period of time, the mist will
disappear as the decrease of room
temperature and humidity decreases.
Cracking noise
This is the sound of friction caused
by expansion and/or contraction of
panel or other parts due to the change
of temperature.
The unit can not be
started up
•Isthepowercutoff?
•Isthepowerplugloose?
(if applicable )
•Isthecircuitprotectiondevice
trippedoff?
•Isvoltagehigherorlower?
(Tested by professionals)
•IstheTIMERcorrectlyused?
Cooling/Heating
effect is poor
•Istemperaturesettingappropriate?
•Istheinletoroutletblocked?
•Isthelterdirty?
•Isthewindoworthedooropen?
•Islowfanspeedset?
•Arethereheatsourcesintheroom?
Remote control does
not transmit signals
•Checkifthereismagneticor
electrical interference near the unit
that may affecting operation of the
remote control. In this case, pull the
plug out and reinsert it.
•Istheremotecontrolwithinits
operatingrangeorobstructed?
Check the condition of the batteries
and replace them if necessary.
•Checkiftheremotecontrol
is damaged.
Water leakage of
indoor unit
•Thehumidityishigh.
•Condensingwateroverows.
•Drainhoseislooseorobstructed.
Troubleshooting
•InDehumidifymode,theindoorfanwill
stop
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kelvinator KSE35CRC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kelvinator KSE35CRC in the language / languages: English as an attachment in your email.

The manual is 1,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info