771563
4
Zoom out
Zoom in
Previous page
1/12
Next page
owner's manual
2
Do not touch the heat exchanger fins.
These fins are sharp and could result in cutting injuries.
Do not place items which might be damaged by moisture
under the indoor unit.
Condensation may form if the humidity is above 80%, the
drain outlet is blocked, or the filter is polluted.
After a long use, check the unit stand and fitting for
damage.
If damaged, the unit may fall and result in injury.
2.
PARTS NAMES
The air conditioner consists of the indoor unit, the
outdoor unit, the connecting pipe and the remote
controller. (see Fig.1)
Force Cooling Control
Force cooling
control Button sw1 Display control button sw2
To avoid oxygen deficiency, ventilate the room
sufficiently if equipment with burner is used together
with the air conditioner.
Arrange the drain hose to ensure smooth drainage.
Incomplete drainage may cause wetting of the building,
furniture etc.
Never touch the internal parts of the controller.
Force Cooling Control
sw1
sw2
MAIN BOARD
(OUTDOOR UNIT)
Fig.2-1
Do not remove the front panel. Some parts inside are
dangerous to touch, and a machine trouble may happen.
Never expose little children, plants or animals directly to
the air flow.
Adverse influence on little children, animals and plants may
result.
Force cooling control of outdoor unit be pressed once that a
order
to force cooling in indoor unit. When the frequency of outdoor
unit
change to 44Hz and then running it; indoor fan run in high
speed.
Press the button again will exit the Force Cooling
Control.
Display function
The function o f text run circulates a s following(12/14/16KW.
Do not allow a child to mount on the outdoor unit or
avoid placing any object on it.
Falling or tumbling may result in injury.
Do not operate the air conditioner when using a room
fumigation - type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of
those who are hypersensitive to chemicals.
Do not place appliances which produce open fire in
places exposed to the air flow from the unit or under the
indoor unit.
It may cause incomplete combustion or deformation of the unit
due to the heat.
Do not install the air conditioner at any place where
flammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.
The appliance is not intended for use by young children
or infirm persons without supervision.
Young children should be supervised to ensure that they
do not play with the appliance.
When capacity of indoor unit greater than the sum of
100%, capacity of indoor unit will be attenuated.
When capacity of indoor unit greater than or equal to the
sum of 120%, in order to ensure the effectiveness of
machine, and then try to open the indoor units at
different time.
The outdoor unit window-shades should be periodic
cleaning in case of being jammed.
This window-shapes is heat dissipation outlet of components, if being
jammed will cause the components to shorten their service life spans
because of overheated for a long time.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
Normal display
Operating mode
(0Standby; 2Cooling;
3—Heating; 4Forced
cooling
Operating fan speed grade
(0Power off)
The total capacity
requirements of the
interior unit
The capacity requirements
of the revised external unit
T3 piping temperature
T4 environment temperature
T5 discharge temperature
(actual) (if it is over one
hundred, it will be only
display the hundreds
place and the tens place)
Display “--
The last fault or protection
code (if there is no fault or
protection code it will be
display “nn”)
The quantities of the operating
interior units
Total quantities of the interior
units
T2 average temperature
Actual voltage AD value
Actual current value
PMV opening
The surface temperature of
the cooling fin
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Mini Amazon II - KMF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Mini Amazon II - KMF in the language / languages: English as an attachment in your email.

The manual is 1.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Mini Amazon II - KMF

Kaysun Mini Amazon II - KMF User Manual - German - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info