Operation
Swing button
Used to initiate the Auto swing feature. When
the operation is ON, press the SWING button
can stop the louver at the desired angle.
Wireless button (optional)
Used to initiate the Wireless function. For the
first time to use Wireless function, press and
hold the swing button for 3 seconds to initiate the
Wireless connextion mode. The LED DISPLAY
shows ‘AP’ to indicate you can set Wireless
connection. If connection (router) is successful
within 8 minutes, the unit will exit Wireless con-
nection mode automatically and the Wireless in-
dicator illuminates. If connection is failure within
8 minutes, the unit exits Wireless connection
mode automatically. After Wireless connection
is successful, you can press and hold SWING
and DOWN (-) buttons at the same time for 3
seconds to turn off Wireless function and the
LED DISPLAY shows ‘OF’ for 3 seconds, press
SWING and UP (+) buttons at the same time to
turn on Wireless function and the LED DISPLAY
shows ‘ON’ for 3 seconds.
NOTE: When you restart the Wireless function,
it may take a period of time to connect to the
network automatically.
Timer button
Used to initiate the AUTO ON start time and
AUTO OFF stop time program, in conjunction
with the + & - buttons. The timer on/off indicator
light illuminates under the timer on/off settings.
Mode button
Selects the appropiate operating mode. Each
time you press the button, a mode is selected in
a sequence that goes from AUTO, COOL, DRY,
FAN and HEAT (cooling only models without).
The mode indicator light illuminates under the
different mode settings.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing) tempe-
rature settings in 1ºC/1ºF (or 2ºF) increments in
a range of 17ºC/62ºF to 30ºC/86ºF (or 88ºF) or
the TIMER setting in a range of 0 ~24 hrs.
NOTE: The control is capable of displaying tem-
perature in degrees Fahrenheit or degrees Cel-
sius. To convert from one to the other, press and
hold the Up and Down buttons at the same time
for 3 seconds.
Sleep (Eco) button
Used to initiate the SLEEP/ECO operation.
Power button
Power switch on/off.
LED display
Shows the set temperature in ºC or ºF (“ºF” no
display for some models) and the Auto-timer se-
ttings. While on DRY and FAN modes, it shows
the room temperature.
Shows Error codes and protection code:
E1- Room temperature sensor error.
E2- Evaporator temperature sensor error.
E3- Condenser temperature sensor error (on
some models).
E4- Display panel communication error.
EC- Refrigerant leakage detection malfunction
(on some models).
P1- Bottom tray is full -- Connect the drain hose
and drain the collected water away. If pro-
tection repeats, call for service.
Note: When one of the above malfunctions oc-
curs, turn off the unit, and check for any obstruc-
tions. Restart the unit, if the malfunction is still
present, turn off the unit and unplug the power
cord. Contact the manufacturer or its service
agents or a similar qualified person for service.
Exhaust hose installation
The exhaust hose and adaptor must be installed
or removed in accordance with the usage mode.
For COOL, HEAT (heat pump type) or AUTO
mode must be installed exhaust hose.
For FAN, DEHUMIDIFY or HEAT (electrical heat
type) mode must be removed exhaust hose.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KP-35 CP10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KP-35 CP10 in the language / languages: English as an attachment in your email.

The manual is 2,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KP-35 CP10

Kaysun KP-35 CP10 User Manual - German - 20 pages

Kaysun KP-35 CP10 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info